Work Instructions & SOPs

SOPs a tech actually follows.

Video SOPs with annotated hotspots on the exact bolt. Gated checkpoints that will not advance without a photo, a signature, or a reading in spec. Full DRAFT → PUBLISHED approval flow with reviewer notes.

Video SOPs Hotspot annotations Gated checkpoints Decision branches

SOP-117 · step 4 of 8

Inspect inlet strainer

PPE Warning 6 min
1
2

Tap hotspots to see the bolt sequence and the direction of rotation.

Checkpoint

Photo + signature required to advance

Capture & advance

Four checkpoint types. None of them optional.

A Dovient SOP checkpoint is a blocking step. Until the tech captures the required proof, the next button stays disabled.

Photo

Tech snaps a photo of the completed state. Geotagged, timestamped, attributed.

Signature

On-screen signature or biometric sign-off. Attributable to the logged-in user.

Reading

Numerical value with configured min / max / target. Out of spec blocks advance.

Checklist

Sub-items with pass/fail. All must pass before the parent step closes.

Four surfaces that turn a binder into a tool.

Author, review, follow, audit. Every step in the product, not in a file share.

Author · image annotation

1
2
3

Pin 2

Grease port, clockwise 1/4 turn

Hotspot authoring

Drag annotation pins onto a photo. Each pin has a label, a direction, and a linked note.

SOP-117 · v4

Pump seal replacement

Draft
Pending review
Pending approval
Approved
Published

Reviewer note

Torque spec verified.

Version workflow

DRAFT → PENDING_REVIEW → PENDING_APPROVAL → APPROVED → PUBLISHED. Reviewer notes on every gate.

Step 5 · decision

Pressure below 4 bar?

Yes → go to step 5a

Inspect suction line

No → go to step 6

Continue PM walk

Branch depth

Up to 3 nested levels

Decision branch

Yes/no branches route the tech. Nested child steps follow the answer.

Step 3 · video

0:31/1:28

Video step

A 90-second walkthrough inline with the step. Tech pauses, scrubs, and finishes the task.

SOPs with the rigour of a standard and the UX of a product.

Nothing buried in a shared drive. Every SOP versioned, searchable, and bound to the work order that uses it.

Video SOPs

Steps reference video URLs. A tech sees the walkthrough inline with the task, not on a separate tab.

Image hotspot annotations

Drag pins onto an asset photo with x/y coordinates and labels. Tech taps the pin on the phone and sees the callout.

Gated QA checkpoints

Photo, signature, reading threshold, or checklist. The checkpoint blocks the next step until the tech captures the proof.

Decision branches and nested steps

Yes/no branches route the tech. Child steps nest up to three levels deep so complex procedures stay readable.

Multi-version approval workflow

DRAFT → PENDING_REVIEW → PENDING_APPROVAL → APPROVED → PUBLISHED. Reviewer and approver notes on every transition.

Time, tools, parts, PPE on each step

Estimated minutes, required tools, required parts, PPE, and a step-level safety warning. No guessing on the floor.

Targeted to asset or location

Pin a SOP to specific assets or asset types so the QR scan on the machine surfaces the right procedure first.

Superseded version preserved

Old versions stay in the audit trail. If a tech ran v3 last month, the evidence pack shows v3, not the current v4.

Copilot SOP drafts

Point the Copilot at an OEM manual or a similar asset's SOP. It drafts the first pass with steps, checkpoints, and PPE filled in.

“

Our tribal knowledge used to live in one person's head. Now it lives in a versioned SOP with a hotspot on the exact bolt and a photo-gated checkpoint. A new hire is productive in two weeks instead of two months.

Maintenance Supervisor · Glass Plant

-60%

Ramp time for new techs

Video + hotspot SOPs replace shoulder-surfing the senior tech.

0

Skipped checkpoints

Gated advance refuses to proceed without the required capture.

100%

Audit evidence

Every run logs the SOP version, the checkpoints hit, and the tech who signed them.

Procedures techs actually follow.

Author one video SOP with a hotspot image and a gated checkpoint. You will feel the difference the first time a new hire runs it alone.