OSHA forklift daily (pre-shift) inspection checklist

A pre-shift forklift checklist built around what OSHA 1910.178 asks for: the walk-around with the truck off, then the operational check. Print one per truck per shift, or run it on a phone.

What OSHA requires

OSHA 29 CFR 1910.178(q)(7) says powered industrial trucks must be examined before being placed in service, at least daily. Where trucks run around the clock, they must be examined after each shift. A truck must not be put in service if the examination shows a condition that affects its safety, and defects must be reported and corrected right away.

Under 1910.178(p)(1) and (q)(1), a truck that needs repair or is unsafe in any way is taken out of service until it has been restored to safe operating condition, and repairs are made by authorized people. The rule applies to every employer that uses forklifts, pallet jacks with a power unit, order pickers, reach trucks and other powered industrial trucks.

How to do the pre-shift check

  1. Before starting the truck, walk around it and go through the visual items: forks, mast, chains, hoses, tires, fluid leaks, guards and the data plate.
  2. Check fluid levels with the engine off: engine oil, hydraulic oil, coolant, and battery water on electric trucks. On LP trucks, check the tank, its mount and the hose connection.
  3. Sit in, fasten the seat belt and start the truck. Test the horn, lights, backup alarm, steering, service brake and parking brake.
  4. Raise, lower and tilt the forks through a full cycle with no load. Listen for noise and watch for jerky movement or leaks.
  5. Mark each item, sign and date the sheet. If anything fails that affects safety, park the truck, tag it out of service and report it to your supervisor.

How often and what records to keep

Do the check once per day before the first use, and once per shift on trucks used around the clock. Any operator who notices a problem during the shift reports it, even if the check was done earlier.

OSHA does not prescribe a form or a retention period for the daily examination. A written or digital record is how you show an inspector that checks were done and that reported defects were fixed. Many warehouses keep the daily sheets for at least a year along with the repair work orders, so they can show the pattern for each truck.

What an OSHA inspector looks at

  • Whether there is a daily check routine and operators know it.
  • Trucks in use with known defects, such as a missing seat belt, a dead horn or backup alarm, or hydraulic leaks.
  • How a failed check gets reported, tagged and repaired before the truck runs again.
  • Operator training and the performance evaluation required at least once every three years (1910.178(l)(4)(iii)).

Forklift pre-shift inspection

Before each shift, for each truck

Visual check, truck off

  • Forks straight, no cracks, locking pins in place
  • Mast and carriage not cracked or damaged
  • Lift chains lubed, no kinks or broken links
  • Hydraulic hoses and fittings not leaking
  • Tires inflated or not chunked, wheel nuts tight
  • Overhead guard and load backrest secure

Fluids and power

  • Engine oil, coolant and hydraulic oil at level
  • No puddles of oil, fuel or coolant under truck
  • Battery charged, cables and plug undamaged
  • LP tank secured, hose and valve not leaking

Operator area

  • Seat belt latches and is not frayed
  • Data plate and warning decals legible
  • Controls labeled and return to neutral
  • Fire extinguisher mounted and charged (if fitted)

Operational check

  • Horn sounds
  • Headlights, strobe and backup alarm work
  • Service brake stops the truck smoothly
  • Parking brake holds
  • Steering turns freely with no play
  • Lift, lower and tilt work smoothly

Inspected by, date and notes go at the bottom of the printed sheet.

Run it in Dovient Lite

Add each forklift as an asset, print its QR label and set a daily schedule with this checklist attached. The operator scans the label, marks each item pass, warning or fail on the phone and adds a photo of anything wrong; the check is saved on that truck's record with who did it and when. A failed item does not open a repair by itself: the operator sends a service request marked as a breakdown, and the supervisor sets the truck to Failed and turns the request into a work order.

Start with Dovient Lite

Sources

Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.

Questions

Does OSHA require a daily forklift inspection?
Yes. 29 CFR 1910.178(q)(7) requires each truck to be examined before it is placed in service, at least daily, and after each shift when trucks are used around the clock.
Does OSHA require a written forklift checklist?
The standard requires the examination, not a specific form. A signed checklist is the usual way to prove the check was done and to track defects until they are fixed.
What do I do if a forklift fails the check?
Take it out of service, tag it, and report it. It stays out of service until an authorized person repairs it and it is safe to run, per 1910.178(p)(1) and (q)(1).
Who should do the daily forklift check?
The trained operator who will drive the truck that shift. Repairs found during the check are done by maintenance staff or the dealer, not by the operator.