What OSHA requires at the dock
- Dockboards, including powered dock levelers, must hold the maximum intended load, and those put in service since January 17, 2017 must keep vehicles from running off the edge. Portable dockboards must be secured and have handholds (29 CFR 1910.26).
- Wheel chocks, sand shoes or similar measures must keep the truck, trailer or rail car from moving while employees are on the dockboard (1910.26(d)).
- Before a forklift boards a highway truck, the truck's brakes must be set and wheel chocks placed under the rear wheels. Fixed jacks may be needed under an uncoupled semitrailer, and trailer floors must be checked for breaks and weakness (1910.178(k) and (m)(7)).
- OSHA accepts a mechanical device that secures the truck or trailer to the dock in place of chocks, when it gives the same protection (OSHA Instruction STD 01-11-007).
- Dock edges 4 feet or more above the ground need fall protection, with a limited exception on the working side of a loading dock when the employer shows it is not feasible, the work is in progress, and only trained, authorized workers have access (1910.28(b)(1)).
- A forklift found unsafe must be taken out of service until repaired (1910.178(q)(1)).
How often to inspect
OSHA does not set an inspection interval for dock equipment, so follow the manufacturer's manuals. A common pattern is a quick check of each door at the start of each shift, a monthly inspection of each dock position by maintenance, and a yearly service of levelers, restraints and overhead doors by the manufacturer's dealer or a qualified door company.
Record each inspection and each repair. When an inspector or insurer asks after an incident, a dated record of the checks is the first thing they want to see.
Common loading dock repairs and their warning signs
- Leveler lip not extending fully or dropping slowly: worn hydraulics or a weak lip spring.
- Uneven leveler deck or cracked welds: overloads or impact damage.
- Torn dock bumpers: trailers hitting the building wall.
- Overhead door off track or slamming: broken cables or worn springs, a serious injury risk.
- Torn seals or shelters: energy loss and water on the dock floor.
Loading dock inspection
Monthly for each dock position; doors checked each shift
Dock leveler
- No cracks or bent plates on deck and lip
- Lip extends fully and rests on trailer bed
- No hydraulic leaks, unit raises and lowers smoothly
- Toe guards and maintenance strut in place
- Capacity label legible
Trailer restraint
- Vehicle restraint engages the rear guard
- Inside and outside signal lights work
- Wheel chocks on hand at each door
Overhead door
- Door opens and closes without binding
- Springs, cables and rollers intact
- Safety edge or photo eye stops the door
Dock area
- Bumpers in place and not torn
- Seals or shelter intact
- Dock lights work
- Floor and approach clear of potholes and spills
- Dock edge marked, guard in place when door open
Inspected by, date and notes go at the bottom of the printed sheet.
Run it in Dovient Lite
Add each dock position, leveler, restraint and overhead door as an asset with its door number, and set a monthly schedule with this checklist attached. The tech marks each item pass, warning or fail on the phone with photos, and the inspection is saved on that dock's record. Operators report a damaged door or leveler from the phone and can mark it a breakdown; the request becomes a work order, and the asset's history shows every repair, part and cost.
Start with Dovient LiteSources
- OSHA, Dockboards, 29 CFR 1910.26
- OSHA, Powered industrial trucks, 29 CFR 1910.178(k), (m)(7), (q)
- OSHA, Duty to have fall protection, 29 CFR 1910.28(b)(1)
- OSHA Instruction STD 01-11-007, Securing trucks or trailers at loading docks
Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.
Questions
- What does OSHA require at a loading dock?
- Dockboards rated for the load and secured, trucks and trailers kept from moving with chocks or a restraint, fall protection at dock edges where feasible, and forklifts in safe condition.
- How often should dock levelers be inspected?
- OSHA does not set an interval. Most manufacturers call for regular checks and a yearly service; a monthly in-house inspection is a common practice.
- Are wheel chocks required if we have vehicle restraints?
- OSHA accepts a mechanical restraint in place of chocks if it gives equivalent protection. Keep chocks on hand for trailers the restraint cannot catch.