OSHA pre-shift forklift inspections on the phone
OSHA 1910.178(q)(7) requires every truck to be examined before it goes into service, at least daily, and after each shift when trucks run around the clock. The operator opens the truck's checklist on the phone (or scans the QR label on the overhead guard, if you use them) and marks forks, mast chains, hydraulic hoses, tires, horn, lights, backup alarm, brakes, steering and seat belt pass, warning or fail, with a photo of anything wrong. Each completed check is saved on the truck's record with the operator's name and the time.
OSHA forklift daily (pre-shift) inspection checklist
Forklift preventive maintenance by hour meter
Give each truck an hour meter and set its planned maintenance every 250 hours: engine oil and filter, hydraulic filter, lube points and mast chain check. When the lead enters a new hour reading, Dovient Lite opens the work order for anything due, with its checklist attached. Date-based jobs, like weekly battery watering on electric trucks, run on the same schedule, and a service can follow whichever comes first.
Forklift preventive maintenance schedule (by hours)
Operators report forklift and dock problems from the floor
An operator sees a leaking tilt cylinder or a dock door that won't close all the way. They pick the truck or the door in the app, describe the problem, add a photo and mark it a breakdown if it can't be used. The maintenance lead is notified, turns the report into a work order, and the operator can see when it's fixed.

Forklift parts on the shelf, cost on the truck
Keep oil and hydraulic filters, mast chain lube, LP tank valves, press-on tires, dock seal pads and door cables in the parts list with a minimum quantity for each. Parts used on a repair come off stock and add to that truck's cost, and anything below its minimum is marked low stock on the list.

Dock doors, levelers and every warehouse repair in one list
Schedule a monthly dock inspection for each door: leveler lip and hinge, hydraulics, vehicle restraint or wheel chocks, door springs and cables, seals and bumpers. Every repair from those checks, along with conveyors, lighting and the battery charging area, is a work order showing who is on it, the photos and the status. The lead assigns jobs from the office, techs update them from a phone, and overdue work shows on the dashboard.
Loading dock safety and maintenance checklistPallet racking inspections with photos
A supervisor walks each aisle monthly with a rack checklist: bent or holed uprights, missing beam locks, damaged base plates and anchors, and load signs in place. A damaged upright is marked fail with a photo of the location, and the supervisor opens a repair work order and unloads the bay until it's fixed. The inspection and the repair both stay on that aisle's record.
Pallet racking inspection checklistWhich forklifts break down most
Each truck's record holds its hour meter, PM schedule, every pre-shift check, repair, part and dollar spent on it. The dashboard counts breakdowns and hours of downtime, shows the average time to repair (MTTR) and between failures (MTBF), and lists the trucks that fail most often, so you know which ones to rebuild and which to replace when the lease ends.
Inspection records for an OSHA visit
Completed pre-shift checks, PM work orders and rack and dock inspections export as a PDF with dates, names, photos and results. When an OSHA compliance officer, your insurer or a customer audit asks how trucks are examined and how defects are handled, you hand over the record for the trucks and dates they want.
OSHA forklift requirements, certification and recordsHow setup works
- 1
Add your forklifts and dock equipment
Import your trucks, dock doors and rack aisles from a spreadsheet (CSV or Excel) or add them one at a time.
- 2
Set checks and service intervals
Choose the pre-shift checklist for each truck, its service interval in hours, and the monthly dock and rack inspections.
- 3
Invite your operators and techs
They install the app and sign in. Operators see the pre-shift check for their truck; techs see the repairs assigned to them.
Set up Dovient Lite with us
Tell us how many forklifts you run. We'll go through your pre-shift checks and service intervals with you and set up your account.
Prefer to start on your own? Start with Dovient Lite
Warehouse checklists and guides
All templates- Template

Forklift warehouses
OSHA forklift daily (pre-shift) inspection checklist
- How-to

Forklift warehouses
Forklift preventive maintenance schedule (by hours)
- Template · Compliance

Forklift warehouses
Loading dock safety & maintenance checklist
- Compliance

Forklift warehouses
OSHA forklift requirements, certification & records
- Template

Forklift warehouses
Pallet racking inspection checklist
- How-to

Forklift warehouses
Warehouse maintenance checklist (conveyors, doors, lighting)
- Template

Forklift warehouses
Warehouse safety & OSHA inspection checklist
Questions
What is warehouse maintenance software?
Software that keeps forklift inspections, scheduled services and building repairs in one record. Dovient Lite does this for small teams: pre-shift forklift checks on a phone, PM by hour meter or date, dock and rack inspections, and a full history for each truck and door.
What does OSHA require for daily forklift inspections?
Under OSHA 1910.178(q)(7), each powered industrial truck must be examined before being placed in service, at least daily, and after each shift where trucks are used around the clock. A truck with a defect that affects safe operation must be taken out of service until it's repaired (1910.178(q)(1)).
Does OSHA require a written forklift inspection record?
The standard requires the examination, not a specific form. A written record is how you show the checks were done and defects were fixed. In Dovient Lite each completed check is saved with the operator's name, the time and photos, and exports as a PDF.
Does a failed check take the forklift out of service automatically?
No. The failed item is saved on the truck's record with its photo. The operator reports it, and the supervisor sets the truck's status to failed and opens the repair work order. The truck shows as down until the repair is closed.
Can I schedule forklift maintenance by hour meter?
Yes. Each truck can have an hour meter, and services can be set every so many hours, every so many days, or whichever comes first. A new reading, entered by the operator or the tech, opens a work order for anything that is due.
How often should pallet racking be inspected?
OSHA has no rack-specific inspection rule, but 1910.176(b) requires stored material to be stable and secure, and the industry standard ANSI MH16.1 asks owners to inspect racking regularly. Many warehouses walk the racks monthly and bring in a qualified rack inspector once a year. Both can be schedules in Dovient Lite.
Can it track operator training and certification dates?
No. Dovient Lite has no certification or license register. OSHA 1910.178(l)(4)(iii) requires an operator performance evaluation at least once every three years; keep those records in your HR or training system.
Is Dovient Lite a warehouse management system (WMS)?
No. It doesn't track pallets, stock of goods, orders or dock appointments. Its parts list is for maintenance parts such as filters, tires and dock seals.
Can I track repair costs across my forklift fleet?
Yes, for each truck and for the forklift fleet as a whole. Labor, parts and outside service charges on each work order add to that truck's cost, and each truck's record shows what it has cost this year next to its breakdowns and downtime.
How much does Dovient Lite cost?
Plans and prices are on the Dovient Lite pricing page: dovient.com/lite/pricing.
Reviewed
Forklifts checked every shift and serviced by the hour meter
