Vaccine temperature log: the CDC ranges
CDC's Vaccine Storage and Handling Toolkit sets the ranges most clinics, pharmacies and state immunization programs use. Refrigerated vaccines are kept between 36°F and 46°F (2°C and 8°C). Frozen vaccines are kept between -58°F and +5°F (-50°C and -15°C). Some vaccines need colder storage; use the package insert.
CDC recommends a digital data logger in each unit and a check of the minimum and maximum temperatures at the start of each workday, recorded on the log. Keep temperature records for at least 3 years, or longer if your state requires it. If you are a Vaccines for Children provider, your state immunization program sets the exact log and retention rules.
Food, medication and lab refrigerators
- Food: the FDA Food Code, which most states adopt, requires cold-held food at 41°F or below. Walk-in coolers and reach-ins are logged at least once a shift in most kitchens.
- Medications and pharmacy: follow the label and your state board of pharmacy; most refrigerated drugs use the same 36°F to 46°F range.
- Labs: follow the reagent or specimen requirements and your accreditation body.
When a reading is out of range
- Label the contents "Do not use" and keep them in the unit, or move them to a unit that is in range.
- Write down the reading, the minimum and maximum, the time, and how long it may have been out of range.
- For vaccines, call the manufacturer and your immunization program before using the doses.
- Find the cause: door left open, power, a failed thermostat, frost. Open a repair if the unit is at fault.
- Record what you did on the log.
Refrigerator and freezer temperature log
At the start of each workday (and at close, if your program asks)
| Date | Time | Refrigerator now (°F) | Refrigerator min / max (°F) | Freezer now (°F) | Freezer min / max (°F) | Action taken | Initials |
|---|---|---|---|---|---|---|---|
The printed log has 10 rows per page.
Run it in Dovient Lite
Add each refrigerator and freezer as an asset with its location and print a QR label for it. Set a daily schedule with a checklist item such as "Refrigerator between 36°F and 46°F", and staff mark it pass or fail on the phone, adding the reading in a comment. Dovient Lite does not read sensors or send alerts, so keep your data logger; use Dovient for the daily check record and the repair history and cost of each unit.
Start with Dovient LiteSources
- CDC, Vaccine Storage and Handling Toolkit
- CDC, Vaccine temperature monitoring
- CDC Pink Book, Chapter 5: Vaccine Storage and Handling
Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.
Questions
- What temperature should a vaccine refrigerator be?
- Between 36°F and 46°F (2°C to 8°C). Freezers for frozen vaccines are kept between -58°F and +5°F.
- How often should I record refrigerator temperatures?
- For vaccines, CDC recommends checking and recording the minimum and maximum at the start of each workday. Food refrigerators are commonly logged once a shift.
- How long do I keep temperature logs?
- CDC recommends at least 3 years for vaccine temperature records, or longer if your state requires it. Food records follow your health department's rules.
- What temperature should a walk-in cooler be for food?
- At or below 41°F to meet the FDA Food Code cold-holding rule adopted by most states.