Commercial pool inspection checklist (health dept, VGB Act)

A daily inspection checklist for hotel, apartment, HOA and club pools and spas, with what the VGB Act and state health codes expect and the records an inspector asks for.

What the VGB Act requires

The Virginia Graeme Baker Pool and Spa Safety Act is a federal law, enforced by the US Consumer Product Safety Commission, that targets drain entrapment. Every public pool and spa must have drain covers that meet the current standard, ANSI/APSP/ICC-16 2017, as set in 16 CFR part 1450. A public pool with a single main drain that can be blocked, or with several drains on the same plane less than three feet apart, also needs a second anti-entrapment device or system.

VGB is about drains. Water quality, fencing, signs, lifeguards and safety equipment are set by your state and local health code, and for pools that staff work around, OSHA rules on chemical handling apply.

State and local pool regulations

Most states license public pools through the health department, require a permit each year, and inspect without notice. Florida regulates public pools under Chapter 64E-9 of the Florida Administrative Code, and Washington under WAC 246-260. Hotel pools, apartment and HOA pools and gym pools are usually all "public" pools under these codes.

Many health departments base their rules on the CDC's Model Aquatic Health Code. CDC's operator guidance calls for a chlorine level of at least 1 ppm in pools and 3 ppm in spas, pH between 7.0 and 7.8, and testing every 2 to 4 hours while open. Your state may set different numbers, and fence height, gate and signage rules vary, so use your local code as the final word.

How often, and what records to keep

  • Before opening each day: the checklist below.
  • Every 2 to 4 hours while open, or as your code says: chlorine and pH test, written in the chemical log.
  • Weekly: filter pressure, backwash as needed, full test kit check.
  • Each season or year: drain covers checked against the service life marked on them, pumps and heaters serviced.
  • Keep the chemical log, daily checklists, drain cover documentation and repair records where the inspector can see them. Your health department sets how long.

Commercial pool daily opening inspection

Daily, before opening

Water and chemistry

  • Chlorine level within your code's range
  • pH between 7.0 and 7.8 (or your code's range)
  • Water clear, main drain visible from the deck
  • Chemical log filled in for the last test

Drains and circulation

  • All drain covers in place, secured, not cracked
  • Drain covers within their marked service life
  • Pump running, no unusual noise or leaks
  • Filter pressure in normal range
  • Skimmer baskets and lids in place

Barrier and deck

  • Fence intact, no gaps or climbable objects nearby
  • Gates self-close and self-latch
  • Deck clean, no trip hazards or standing water
  • Depth markers and no-diving signs legible

Safety equipment and signs

  • Ring buoy and reaching pole in place
  • Emergency phone working, number posted
  • Pool rules and capacity sign posted
  • First aid kit stocked

Chemical room

  • Chemicals stored apart and labeled
  • Room ventilated and locked
  • Safety data sheets and PPE available

Inspected by, date and notes go at the bottom of the printed sheet.

Run it in Dovient Lite

Add the pool, spa, pumps, filters and heaters as assets, attach this checklist to a daily schedule, and a work order opens each day. Staff mark each item pass, warning or fail on the phone and add photos of anything wrong; the completed checklist stays on the pool's record with who did it and when. A failed item does not open a repair on its own, so the person doing the check opens a work order for the fix.

Start with Dovient Lite

Sources

Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.

Questions

What is the VGB Act?
A federal law that requires public pools and spas to have drain covers meeting the current CPSC standard, and a second anti-entrapment system where a single drain could be blocked. It does not cover water chemistry or fencing.
How often should a commercial pool be inspected?
Staff should check it every day before opening and test chemistry every 2 to 4 hours while open, or as your state code says. The health department usually inspects at least once a year.
What records does the health inspector want to see?
The chemical log, daily opening checks, drain cover documentation, and repairs to pumps, filters and safety equipment. Ask your health department how long to keep them.
Do OSHA pool regulations apply?
OSHA has no pool-specific standard, but its rules on hazardous chemicals and protective equipment apply to staff who handle pool chemicals.