How to build a preventive maintenance plan
- List your equipment: every machine, unit or system you would hate to lose, with its location, make, model and serial number.
- Rank it: what stops work, costs the most to repair, or is a safety or code item comes first.
- Pull the intervals from the manuals: oil, filters, belts, lubrication, inspections. Where there is no manual, start with the checklist below.
- Pick a trigger for each task: a date (weekly, monthly, yearly) or a meter reading (run hours, miles).
- Assign each task to a person or a contractor, and decide what they record.
- Review every few months. Shorten intervals on equipment that keeps failing, and lengthen them where checks never find anything.
Preventive maintenance schedule template
Most plans settle into a few frequencies. Use these as a starting point and adjust for each machine's manual and how hard it runs.
- Daily or each shift: operator walk-around for leaks, noises, gauges and guards.
- Weekly: clean, lubricate where the manual says weekly, check belts and fluid levels.
- Monthly: the full checklist below, filter checks, safety device tests.
- Quarterly: tighten connections, check alignment and wear parts, inspect electrical panels.
- Yearly: major service, calibration, contractor inspections and any code-required tests.
- By meter: oil and filter changes by run hours or miles, as the manual specifies.
Records to keep
For each task: the date, the asset, who did it, the result of each check, the parts used and any follow-up repair. Most general equipment has no legal record requirement, but regulated items do, such as fire extinguishers, boilers, lifts, forklifts and commercial vehicles. A record per asset shows what was done, what it cost and whether the plan is working.
General equipment preventive maintenance
Monthly, for each asset (adjust to the manual)
Visual and safety
- Guards, covers and panels in place
- Emergency stop and safety switches work
- Warning labels and nameplate readable
- Area around the equipment clean and clear
Mechanical
- No unusual noise, vibration or heat
- Belts tensioned, not cracked or glazed
- Bearings and moving parts lubricated
- Fasteners and mounts tight
- No worn, loose or damaged parts
Fluids and filters
- Oil, coolant and hydraulic levels correct
- No leaks at seals, hoses or fittings
- Air and fluid filters clean or replaced
Electrical
- Cords, plugs and cables not damaged
- Panel doors closed, no burnt smell or marks
- Controls, lights and indicators work
Records
- Meter reading recorded (hours or miles)
- Last service date and next due date noted
- Problems found written up for repair
Inspected by, date and notes go at the bottom of the printed sheet.
Run it in Dovient Lite
Add your assets one at a time or import them from a spreadsheet, then create a schedule for each task, by date (daily, weekly, monthly, yearly or every N) or by meter reading in hours or miles, with a checklist attached. A work order opens when each schedule is due; the tech marks each item pass, warning or fail on the phone, and the completed checklist stays on the asset's record with who did it and when. The dashboard shows open and overdue work orders, so you can see which PMs are slipping.
Start with Dovient LiteQuestions
- What should a preventive maintenance checklist include?
- Safety devices and guards, signs of wear, lubrication, fluid levels and leaks, filters, electrical condition and a meter reading. Add the specific tasks from each machine's manual.
- How often should preventive maintenance be done?
- Follow the manufacturer's intervals first. Without them, a daily operator check, a monthly inspection and a yearly service is a common starting point, with meter-based service for equipment that runs a lot.
- What records do I need for preventive maintenance?
- The date, asset, who did the work, the result of each check, parts used and any follow-up. Regulated equipment such as vehicles, lifts and fire equipment has its own record rules.
- What is the difference between a PM checklist and a PM schedule?
- The checklist says what to check on a visit. The schedule says when each visit happens for each asset.