Vehicle maintenance log & tracker (printable + digital)

A vehicle maintenance log with the columns FMCSA expects for trucks, how often to service and inspect, and how long to keep the records. Use it as a spreadsheet, a printed truck log book, or on a phone.

What FMCSA requires in a truck maintenance log

If you run commercial motor vehicles in interstate commerce (generally 10,001 pounds or more, or vehicles carrying passengers above the set limits), 49 CFR 396.3 requires you to systematically inspect, repair and maintain every vehicle you control and keep records for each one. Many states apply the same rules to intrastate carriers.

Each vehicle's record must include an identification of the vehicle (company unit number if marked, make, serial number and year), a way to show the nature and due date of each inspection and maintenance task, and a record of inspections, repairs and maintenance with their date and nature. Keep these records where the vehicle is housed or maintained for 1 year, and for 6 months after the vehicle leaves your control (396.3(c)).

The other inspection records that go with it

  • Driver vehicle inspection reports (396.11): a written post-trip report when a defect is found or reported, with the certification of repairs. Keep them for 3 months.
  • Annual periodic inspection (396.17): every vehicle, including each trailer, must pass an inspection covering the items in appendix A to part 396 at least once every 12 months, with proof on the vehicle.
  • The annual inspection report must be kept for 14 months from the date of the inspection (396.21).

How often to service fleet vehicles

FMCSA does not set mileage intervals. It requires a systematic program, so the intervals come from the manufacturer's service schedule and your own operating conditions. Most fleets service by miles or engine hours and do a yearly inspection by date.

  • Every trip: driver pre-trip check, and a post-trip report when a defect is found.
  • By miles: oil and filter, fuel filters, tire rotation, grease, at the intervals in the service manual.
  • Periodically: brake adjustment and lining checks, belts and hoses, battery, coolant.
  • Yearly: the annual DOT inspection, plus any state inspection.

Using a fleet maintenance spreadsheet

A spreadsheet with one row per service works for a few vehicles. Use one tab per vehicle, or one sheet with a unit number column, and fill in the columns below every time a truck is serviced, inspected or repaired. The weak spot is the due date: a spreadsheet does not tell anyone that a truck is past its oil change, so someone has to check it every week.

Vehicle maintenance log

One row each time a vehicle is serviced, inspected or repaired

DateUnit numberOdometer (miles)Inspection, service or repair doneParts usedCostNext due (date or miles)Done by

The printed log has 10 rows per page.

Run it in Dovient Lite

Add each truck and trailer as an asset with its unit number, make, serial number and year, or import the list from your fleet spreadsheet. Set service schedules by miles and the annual inspection by date, each with a checklist; when a mileage reading or date makes a service due, a work order opens. Drivers report defects from the phone with a photo, and every repair, part and cost lands on the vehicle's record, which exports as a PDF for an auditor.

Start with Dovient Lite

Sources

Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.

Questions

How long do I keep truck maintenance records?
Keep the maintenance records for 1 year where the vehicle is housed or maintained, and for 6 months after the vehicle leaves your control. Annual inspection reports are kept 14 months and driver inspection reports 3 months.
How often should a fleet service its vehicles?
FMCSA does not set intervals. Follow the manufacturer's schedule by miles or engine hours, and do the annual inspection on every vehicle at least once every 12 months.
What has to be in a vehicle maintenance log?
The vehicle's identification, the type and due date of each inspection and maintenance task, and a dated record of each inspection, repair and service.
Is a spreadsheet good enough for a fleet maintenance log?
Yes, if it has the required information and someone keeps it current. It gets harder as the fleet grows, because a spreadsheet does not open the next service when it is due.