What FMCSA requires
Under 49 CFR 396.3(a), every motor carrier must systematically inspect, repair and maintain all motor vehicles under its control. The rule does not set mileage intervals. It leaves the schedule to you, and an auditor checks that you have one and follow it.
Section 396.3(b) says that for each vehicle you control for 30 consecutive days or more, you keep: an identification of the vehicle (company number, make, serial number, year), a means to show the nature and due date of each inspection and maintenance task, and a record of inspections, repairs and maintenance with their date and nature. These records stay where the vehicle is housed or maintained for 1 year, and for 6 months after the vehicle leaves your control (396.3(c)).
Each commercial motor vehicle also needs an annual inspection under 396.17, and that report is kept for 14 months (396.21). Driver vehicle inspection reports (396.11) are kept for 3 months.
A starting fleet maintenance schedule
These intervals are common starting points. Your engine and axle makers' manuals, the oil you run, and your duty cycle (stop-and-go, idle time, towing) come first. Trucks in severe service usually need the shorter end.
- Every day: driver pre-trip and post-trip inspection.
- Every 5,000 to 7,500 miles (light duty) or 15,000 to 25,000 miles (heavy duty): engine oil and filter, chassis lube, visual brake and tire check.
- Every 5,000 to 7,500 miles: tire rotation on light-duty vehicles.
- Every 3 months: brake inspection and adjustment check, lights, wipers, belts and hoses, battery terminals.
- Every 30,000 miles or yearly: air filter, fuel filters, cabin filter, coolant test.
- Every 12 months: annual DOT inspection under 396.17 for each commercial motor vehicle.
- By the maker's schedule: transmission and differential fluid, coolant change, DEF system service.
How to set up the schedule
- List every vehicle with unit number, VIN, make, model, year and current odometer.
- Group vehicles by type and duty, and pick an interval for each service from the manual.
- Write a short checklist for each service (A service, B service, annual) so every tech does the same work.
- Record the odometer on every work order so the next due mileage is right.
- Review each month: what is overdue, what failed between services, and which units cost the most.
Fleet PM service (A service)
Every oil change interval, by miles or months
Engine
- Oil and filter changed, level correct
- No oil, fuel or coolant leaks
- Belts and hoses not cracked or soft
- Air filter clean or replaced
Brakes and tires
- Brake lining above minimum thickness
- Slack adjusters in adjustment (air brakes)
- Tires at set pressure, tread above minimum
- Wheel nuts tight, no cracked rims
Chassis and steering
- Chassis lubed at all fittings
- No play in steering linkage
- Suspension springs and mounts not broken
- Exhaust secure, no leaks near cab
Cab and lights
- Headlights, signals and brake lights work
- Horn, wipers and washers work
- Mirrors secure and not cracked
- Fire extinguisher and triangles on board
Inspected by, date and notes go at the bottom of the printed sheet.
Run it in Dovient Lite
Add each vehicle as an asset with its unit number, then set preventive maintenance schedules by miles for oil and lube, and by date for brake checks and the annual DOT inspection, each with its checklist. A work order opens when a schedule is due; the mechanic marks the checklist on the phone, logs the parts used, and the work stays on that truck's record with who did it and when. Completed work orders export as PDF for an audit.
Start with Dovient LiteSources
- FMCSA, Inspection, repair, and maintenance, 49 CFR 396.3, 396.11, 396.17, 396.21
Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.
Questions
- How often should fleet vehicles get preventive maintenance?
- Most fleets service light-duty vehicles every 5,000 to 7,500 miles and heavy trucks every 15,000 to 25,000 miles, with a time limit such as 3 or 6 months for low-mileage units. Use the maker's manual and your duty cycle to set the final numbers.
- What maintenance records does FMCSA require?
- Under 49 CFR 396.3(b): vehicle identification, a way to show the type and due date of each maintenance task, and a dated record of inspections, repairs and maintenance. Keep them 1 year, and 6 months after the vehicle leaves your control.
- Does FMCSA set oil change intervals?
- No. Part 396 requires a systematic program and records but leaves intervals to the carrier. Auditors check that you follow your own schedule.
- How long do I keep the annual DOT inspection report?
- 14 months from the date of the inspection, under 49 CFR 396.21(b).