What a DVIR is and who needs one
A driver vehicle inspection report (DVIR) is the written report a commercial driver prepares at the end of each day's work on each vehicle operated, under 49 CFR 396.11(a). It applies to motor carriers subject to the Federal Motor Carrier Safety Regulations.
Section 396.11(a)(5) exempts private motor carriers of passengers (nonbusiness), driveaway-towaway operations, and carriers that operate only one commercial motor vehicle. Intermodal chassis provided by an equipment provider follow 396.11(b) instead.
What the rule requires
- The report covers at least: service brakes including trailer brake connections, parking brake, steering mechanism, lighting devices and reflectors, tires, horn, windshield wipers, rear vision mirrors, coupling devices, wheels and rims, and emergency equipment (396.11(a)(1)).
- It identifies the vehicle and lists any defect that would affect safe operation or cause a breakdown. A driver who runs more than one vehicle in a day prepares a report for each one (396.11(a)(2)(i)).
- Drivers are not required to prepare a report if no defect or deficiency is found or reported to them (396.11(a)(2)(i)).
- Before the vehicle runs again, the carrier repairs any listed defect likely to affect safety and certifies on the report that it was repaired or that no repair was needed (396.11(a)(3)).
- Before driving, the next driver must be satisfied the vehicle is safe, review the last DVIR, and sign it to acknowledge the repair certification (396.13).
Records to keep and what an auditor checks
Keep the original DVIR, the repair certification and the driver's review signature for 3 months from the date the report was prepared (396.11(a)(4)). Reports may be kept electronically (396.13(d) and 390.32).
In a compliance review or roadside inspection, the auditor compares your DVIRs with repair records and roadside violations. A defect that shows up at roadside but was never written up, or a written defect with no repair certification before the next trip, is the usual finding.
How to run DVIRs day to day
- Give each driver the template for each tractor and trailer they run.
- At the end of the day, the driver checks the 11 items and writes up any defect with a photo if possible.
- The shop reviews every report with a defect, repairs or decides no repair is needed, and signs the certification.
- The next driver reviews the last report and signs before the trip.
- File the reports by vehicle and keep them at least 3 months.
Driver vehicle inspection report (DVIR)
End of each day's work, for each vehicle operated
Brakes and steering
- Service brakes work, trailer air lines connected
- Parking brake holds
- Steering has no excess play or binding
Lights and visibility
- Headlights, signals, brake and marker lights work
- Reflectors and reflective tape in place
- Windshield wipers clear the glass
- Rear vision mirrors secure and not cracked
- Horn works
Tires, wheels and coupling
- Tires inflated, no cuts or bulges
- Wheels and rims not cracked, lug nuts tight
- Fifth wheel or hitch locked, safety chains on
Emergency equipment
- Fire extinguisher charged and mounted
- Warning triangles on board
- Spare fuses on board (if required)
Sign-off
- Defects listed, or no defects found
- Driver name, date and vehicle number recorded
- Repairs certified before next trip
Inspected by, date and notes go at the bottom of the printed sheet.
Run it in Dovient Lite
Add each tractor and trailer as an asset, print its QR label, and set a daily schedule with this checklist attached. The driver scans the label, marks each item pass, warning or fail on the phone and adds a photo of any defect; the report is saved on that vehicle's record with the driver's name and time. For a defect, the driver sends a service request, the shop turns it into a work order, and the completed work order is the repair record you can export as PDF.
Start with Dovient LiteSources
- FMCSA, Driver vehicle inspection report(s), 49 CFR 396.11
- FMCSA, Driver inspection, 49 CFR 396.13
Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.
Questions
- Is a DVIR mandatory?
- Yes, for motor carriers under the FMCSRs, except the groups exempted in 396.11(a)(5). A driver does not have to prepare a report on a day when no defect is found or reported.
- How long do I keep DVIRs?
- 3 months from the date the report was prepared, along with the repair certification and the next driver's signature (49 CFR 396.11(a)(4)).
- What is the difference between a pre-trip inspection and a DVIR?
- Under 396.13 the driver must be satisfied the vehicle is safe and review the last DVIR before driving. The DVIR itself is the written report at the end of the day's work.
- Can DVIRs be electronic?
- Yes. 396.13(d) allows the reports to be created and kept electronically under 49 CFR 390.32.