Dovient

Template · Compliance

Annual DOT inspection checklist

What is a DOT inspection, what the annual inspection must cover under 49 CFR 396.17, who can do it, and a checklist built on the federal minimum standards.

What the annual DOT inspection is

The annual DOT inspection, also called the periodic inspection, is required by the Federal Motor Carrier Safety Regulations for every commercial motor vehicle a motor carrier operates in interstate commerce (49 CFR 396.17). Each vehicle in a combination counts on its own: the tractor, each trailer and a converter dolly each need an inspection.

A vehicle cannot be operated unless every component in Appendix A to Part 396, the Minimum Periodic Inspection Standards, has passed an inspection in the last 12 months. Proof of the inspection must be on the vehicle: a copy of the report, or a sticker or decal that shows the inspection date, the name and address of the carrier or other party that holds the report, the vehicle's identification if it is not clearly marked, and a statement that the vehicle passed.

A state periodic inspection program that meets the federal standards counts as the annual inspection. Roadside inspections are a separate thing, done by enforcement officers.

Who can do it and what records to keep

  • The carrier can do its own inspections, or use a commercial garage, leasing company or truck stop as its agent (396.17(d) and (e)).
  • The inspector must be qualified under 396.19: understand the standards, have the tools and know the methods, and have a state or federal training certificate or at least one year of training or experience. Keep evidence of each inspector's qualifications while they do inspections for you and for one year after.
  • The report must identify the inspector, the carrier, the date, the vehicle, the components inspected and the results, and certify the inspection (396.21(a)).
  • Keep the original or a copy for 14 months from the report date, where the vehicle is housed or maintained, available to officials on request (396.21(b)).

What the inspection covers

Appendix A lists the defects that fail a vehicle in these areas: brake system, coupling devices, exhaust system, fuel system, lighting devices, safe loading, steering, suspension, frame, tires, wheels and rims, windshield glazing and wipers, plus motorcoach seats and rear impact guards where they apply. The checklist below follows those areas. Use the appendix itself for the exact limits, such as brake pushrod stroke and tire tread depth.

Annual DOT periodic inspection

At least every 12 months, for each vehicle and trailer

Brakes

  • Service brakes work on every braked axle
  • Pushrod stroke within readjustment limits
  • No audible air leaks at chambers or lines
  • Linings, drums and rotors within limits
  • Parking brake holds
  • Low air warning and compressor work

Coupling, frame and suspension

  • Fifth wheel and kingpin secure, not worn
  • Safety chains and hitch secure
  • No cracks or broken frame members
  • Springs, hangers and U-bolts intact
  • Air suspension holds pressure

Steering

  • Steering wheel lash within limits
  • Steering gear box and linkage secure
  • Power steering works, no leaks

Tires and wheels

  • Tread depth at or above minimum
  • No cuts, bulges or exposed cord
  • Lug nuts present and tight
  • Wheels and rims not cracked or bent

Lights, glass and wipers

  • All required lamps and reflectors work
  • No windshield damage in driver's view
  • Wipers work and blades in good condition

Exhaust, fuel and other

  • No exhaust leaks under the cab
  • Fuel tanks secure, caps on, no leaks
  • Rear impact guard in place, if required
  • Report and decal or copy on the vehicle

Inspected by, date and notes go at the bottom of the printed sheet.

Run it in Dovient Lite

Add each truck and trailer as an asset, and set a yearly schedule for the annual inspection with this checklist attached, alongside oil and service schedules by miles or engine hours. The work order opens when it is due; the inspector marks each item pass, warning or fail on the phone, attaches the signed report, and the completed inspection stays on the vehicle's record. Export it as PDF to keep where the vehicle is maintained.

Start with Dovient Lite

Sources

Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.

Questions

What is a DOT inspection?
Usually it means the annual periodic inspection required by 49 CFR 396.17 for every commercial motor vehicle. It can also mean a roadside inspection by an enforcement officer.
How often is a DOT inspection required?
At least once every 12 months for each vehicle, including each trailer.
How long do I keep DOT annual inspection reports?
Keep the original or a copy for 14 months from the report date, where the vehicle is housed or maintained, and keep proof of the inspection on the vehicle.
Can my own mechanic do the annual inspection?
Yes, if they meet the qualifications in 49 CFR 396.19 and you keep evidence of those qualifications.