What the rules require
Before driving a commercial motor vehicle, the driver must be satisfied that it is in safe operating condition (49 CFR 396.13). Section 392.7 lists the parts that must be in good working order: service brakes and trailer brake connections, parking brake, steering, lights and reflectors, tires, horn, wipers, mirrors, coupling devices, wheels and rims, and emergency equipment.
The driver must also review the last driver vehicle inspection report (DVIR) if it listed defects, and sign it to show the repairs were certified (396.13). At the end of the day the driver prepares a DVIR for each vehicle driven; a written report is only required when a defect is found or reported (396.11). The carrier keeps DVIRs, repair certifications and the driver's review for three months.
Who it applies to
These rules apply to commercial motor vehicles in interstate commerce, which includes trucks with a gross vehicle weight rating of 10,001 pounds or more. Many states apply the same rules to intrastate trucks. The DVIR rule in 396.11 does not apply to a carrier operating only one commercial vehicle, but the pre-trip check in 392.7 still does. Light vans and pickups are not covered, but the same checklist is good practice for them.
How to run the pre-trip inspection
- Read the last DVIR and confirm any listed defect was repaired and signed off.
- Walk around the truck and trailer, then check the cab, using the checklist below.
- Start the engine and check gauges, air pressure, brakes, horn, wipers and lights.
- Mark each item, and photograph anything that is worn, leaking or broken.
- If a safety item fails, do not drive. Report it so the truck is repaired before it goes out.
Truck inspection records to keep
- DVIRs, repair certifications and driver review: 3 months (49 CFR 396.11).
- Inspection, repair and maintenance records per vehicle: 1 year, and 6 months after the vehicle leaves your control (396.3).
- Annual inspection report: 14 months, with proof of it on the vehicle (396.17 and 396.21).
Pre-trip vehicle inspection
Before each trip, for each vehicle
Brakes and steering
- Service brakes stop the truck straight and firm
- Parking brake holds the truck
- Air pressure builds normally, no audible leaks
- Trailer brake lines connected, not chafed
- Steering has no excess play or binding
Lights and visibility
- Headlights, tail, brake and turn lights work
- Reflectors and markers clean and in place
- Windshield not cracked in the driver's view
- Wipers and washer work
- Mirrors in place, clean and adjusted
Tires, wheels and rims
- Tires inflated, no cuts, bulges or exposed cord
- Tread depth above the legal minimum
- Lug nuts tight, no rust trails
- Rims not cracked or bent
Coupling and cargo
- Fifth wheel locked, jaws closed on the kingpin
- Safety chains and hitch secure
- Cargo secured, doors closed and latched
Cab and emergency equipment
- Horn works
- Gauges read normal after start-up
- Fire extinguisher charged and secured
- Warning triangles on board
- Last DVIR reviewed and signed
Inspected by, date and notes go at the bottom of the printed sheet.
Run it in Dovient Lite
Add each truck and trailer as an asset, print its QR label, and set a daily schedule with this checklist attached. The driver scans the label, marks each item pass, warning or fail on the phone and adds a photo of anything wrong; the check is saved on that truck's record with who did it and when. A driver can also report a defect as a service request and mark it a breakdown, and the request becomes the repair work order.
Start with Dovient LiteSources
- FMCSA, Equipment, inspection and use, 49 CFR 392.7
- FMCSA, Driver inspection, 49 CFR 396.13
- FMCSA, Driver vehicle inspection report(s), 49 CFR 396.11
- FMCSA, Inspection, repair, and maintenance, 49 CFR 396.3
Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.
Questions
- Is a pre-trip inspection required by law?
- Yes, for commercial motor vehicles. 49 CFR 396.13 requires the driver to be satisfied the vehicle is safe before driving, and 392.7 lists the parts that must be in good working order.
- Does the driver have to fill out a form every morning?
- Federal rules require a written report at the end of the day only when a defect is found or reported. Many fleets still have drivers complete a checklist every trip, because it proves the check was done.
- How long do I keep truck inspection reports?
- Keep DVIRs and repair certifications for 3 months. Keep each vehicle's inspection, repair and maintenance records for 1 year and for 6 months after the vehicle leaves your control.
- How often should a fleet do pre-trip inspections?
- Before each trip, and at least once each day the truck is driven. Pair it with a post-trip check so defects are found at the end of the shift, when there is time to fix them.