Dovient

Compliance

Turnout gear inspection (NFPA 1851)

What NFPA 1851 asks a fire department to do with structural turnout gear: inspection, cleaning, repair, retirement and records, and how to track each set.

What NFPA 1851 is

NFPA 1851 is the standard on selection, care and maintenance of structural and proximity firefighting protective ensembles: coats, pants, helmets, hoods, gloves and boots. It is a consensus standard, so it becomes a requirement when your state, your department policy or your insurer adopts it, and it is what investigators compare to after an injury.

NFPA has consolidated 1851 with the SCBA care standard into NFPA 1850. Many departments still work from the 2020 edition of 1851. Follow the edition your department or state has adopted; the intervals below are from the 2020 edition of NFPA 1851.

Turnout gear inspection and cleaning

  • Routine inspection: by the firefighter after every use, looking for soiling, contamination, tears, burns, damaged hardware and closures.
  • Advanced inspection: at least once every 12 months, and whenever a routine inspection finds possible damage. Done by a trained person in the department or an independent service provider, and includes checking each layer and the seams, reflective trim and fit of liner to shell.
  • Routine cleaning: after use when gear is soiled, brushing off debris and rinsing.
  • Advanced cleaning: at least every six months, so at least twice a year, with one of them done with the annual advanced inspection. Also after any fire exposure or contamination.
  • Repairs: done by the manufacturer, a verified independent service provider, or a trained person in the department for basic repairs.

Retirement

Structural ensemble elements must be retired no more than 10 years from the date of manufacture, regardless of condition. Gear is retired earlier when it fails an inspection and cannot be repaired, or is contaminated beyond cleaning. Retired gear should be destroyed or clearly marked so it is never put back in service; some departments keep a marked set for training only.

Records to keep and what is checked

After a firefighter injury or during an ISO, state or insurance review, the questions are the same: is each set within 10 years, when was it last inspected and cleaned, and who did it. A record per set, by serial number, answers them.

  • One record per element (coat, pants and so on): manufacturer, serial number, date of manufacture and who it is issued to.
  • Each advanced inspection, with the date, who did it and the findings.
  • Each advanced cleaning, decontamination and repair, with the date and who did it.
  • Retirement date and reason.

Run it in Dovient Lite

Add each coat and pair of pants as an asset with its serial number, and put the member it is issued to in its location field. Set a yearly advanced inspection schedule and a six-month advanced cleaning schedule with checklists; whoever does the work marks each item pass, warning or fail on the phone with photos. Each element's record shows every inspection, cleaning and repair with who did it and when, and completed work exports as PDF.

Start with Dovient Lite

Sources

Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.

Questions

How often does turnout gear need an advanced inspection?
At least once every 12 months under NFPA 1851 (2020 edition), and whenever a routine inspection finds possible damage.
How often should turnout gear be cleaned?
Advanced cleaning at least every six months, so twice a year, under the 2020 edition, and after any fire exposure or contamination. Routine cleaning after use when soiled.
How long does turnout gear last?
No more than 10 years from the date of manufacture for structural gear, and sooner if it fails inspection and cannot be repaired.
Is NFPA 1851 required by law?
It is a consensus standard, so it is binding where a state, the department or an insurer adopts it. Even where it is not adopted, it is the yardstick used to judge gear care after an injury.