Fire apparatus daily truck check & NFPA 1911 inspection

A fire truck checklist for the daily apparatus check at shift change, plus what NFPA 1911 (now part of NFPA 1910) expects for inspection, maintenance and the annual pump test.

NFPA 1911 and NFPA 1910

NFPA 1911 was the standard for the inspection, maintenance, testing and retirement of in-service fire apparatus. In 2024 NFPA combined it with NFPA 1912 (refurbishing), NFPA 1925 (fire boats) and NFPA 1071 (emergency vehicle technician qualifications) into a single standard, NFPA 1910. Many departments and state rules still refer to 1911, so you will see both numbers. Use the edition your jurisdiction has adopted.

The standard expects a daily or weekly operator inspection of each apparatus, a periodic inspection and preventive maintenance by a qualified technician on the manufacturer's schedule, out-of-service criteria for defects that make the truck unsafe, and performance tests. Fire pumps get a service test at least once a year and after major pump repair, and aerial devices get yearly testing as well.

How to run the daily truck check

  1. At shift change, the driver/operator walks the apparatus with the checklist below.
  2. Start the truck, check gauges and warning lights, and run the pump briefly if your SOP calls for it.
  3. Check each compartment against its inventory, and SCBA on the riding positions.
  4. Record the result and sign it. Report any defect to the officer.
  5. If a defect meets your out-of-service criteria, take the truck out of service and notify the maintenance officer.

Records to keep

Keep them for the life of the apparatus. They are what an ISO review, insurer or crash investigation asks for.

  • Daily and weekly operator checks, signed and dated.
  • Preventive maintenance by engine hours, miles or date.
  • Annual pump service test results and aerial test results.
  • Repairs, who did them, parts used, and out-of-service and return-to-service times.

Fire apparatus daily truck check

Daily, at shift change

Walk-around

  • No fluid leaks under the truck
  • Tires inflated, tread and sidewalls good
  • Lug nuts tight, no rust streaks
  • Body, ladders and mounted equipment secure
  • Compartment doors close and latch

Engine and fluids

  • Engine oil at the full mark
  • Coolant at the proper level
  • Power steering and transmission fluid OK
  • DEF and fuel at least three-quarters full
  • Belts and hoses not cracked or loose

Cab and driving

  • Air pressure builds, low-air warning works
  • Brakes and parking brake hold
  • Gauges normal, no warning lights
  • Emergency lights and siren working
  • Headlights, turn signals and backup alarm working
  • Mirrors clean and adjusted

Pump and water

  • Water tank full
  • Foam tank full, if equipped
  • Pump engages and primes
  • Pump panel gauges and relief valve working

Equipment

  • SCBA at each seat, cylinders full
  • Compartments match the inventory
  • Portable radios charged
  • Hand lights and thermal imager charged

Inspected by, date and notes go at the bottom of the printed sheet.

Run it in Dovient Lite

Add each engine, ladder and tender as an asset and set a daily schedule with this checklist, so a work order opens each day for the driver/operator. Set preventive maintenance by engine hours or miles from meter readings, and the annual pump test as a yearly schedule with its own checklist. Items are marked pass, warning or fail on the phone with photos, and the truck's record shows every check, repair, part and cost.

Start with Dovient Lite

Sources

Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.

Questions

What is NFPA 1911?
The standard for inspecting, maintaining, testing and retiring in-service fire apparatus. Since 2024 its content is part of NFPA 1910.
How often does a fire pump need to be tested?
A pump service test at least once a year and after major pump repair, under NFPA 1911, now NFPA 1910.
How often should fire apparatus be checked?
An operator check daily or at each shift change is common practice, with preventive maintenance by a qualified technician on the manufacturer's schedule.
What records does a fire department need for its trucks?
Signed daily checks, preventive maintenance, annual pump and aerial test results, repairs and out-of-service times, kept for the life of each apparatus.