The standards, in simple terms
Fire hose testing comes from NFPA 1962, which covers the care, use, inspection, service testing and replacement of fire hose, couplings, nozzles and appliances. Ground ladder testing comes from NFPA 1932, which covers the use, maintenance and service testing of in-service fire department ground ladders. NFPA has combined both, along with other equipment standards, into NFPA 1930. Many departments and state rules still cite 1962 and 1932, so use the edition your jurisdiction has adopted.
These are NFPA standards, not federal law. They become requirements when your state, local government or department adopts them, and insurers and ISO reviews expect them to be followed.
What has to be done, and how often
Test pressures, procedures and loads are set in the standard for each hose type and ladder type. Many departments use a certified testing company for ladders and do hose testing in-house with a hose testing machine.
- Fire hose: inspect after each use, and service test each length at least once a year and after repair or damage, such as being run over. Hose that fails is removed from service, repaired and retested, or condemned.
- Hose made before July 1987 is to be taken out of service under NFPA 1962.
- Nozzles and hose appliances: inspect after use and test on the schedule in the standard.
- Ground ladders: inspect after each use and at least monthly, and service test at least once a year, before first use, and after any event that may have damaged the ladder, such as heat exposure or a heat sensor label that has changed.
Records to keep
Each hose length and each ladder needs its own identification number and its own record. For hose, record the length, size, type, manufacturer, date in service, each service test with date, pressure and result, repairs, and the date it was taken out of service. For ladders, record the type, length, manufacturer, date in service, each inspection and service test with result, repairs, and removal from service. Keep the record for the life of the hose or ladder.
What an inspector or ISO reviewer looks at
- That every hose length and ladder on the apparatus has a current test.
- That failed items were removed from service and not put back without a passing retest.
- That the records match what is on the trucks.
Run it in Dovient Lite
Add each hose length and ground ladder as an asset with its ID number as the name and its apparatus or station as the location, and print a QR label for each. Set a yearly schedule with a service test checklist and a monthly schedule for ladder inspections, so a work order opens when each is due. The tester marks each item pass, warning or fail on the phone, and the result stays on that hose or ladder's record with who did it and when.
Start with Dovient LiteSources
- NFPA 1930 (incorporates NFPA 1962 fire hose and NFPA 1932 ground ladders)
- Washington State, Ground ladders (example of a state rule adopting ladder testing), WAC 296-305-06006
Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.
Questions
- How often does fire hose need to be tested?
- Each length is service tested at least once a year under NFPA 1962, now part of NFPA 1930, and again after repair or damage.
- How often do ground ladders need to be tested?
- At least once a year, before first use, and after any event that may have damaged the ladder, such as heat exposure.
- What records do I need for hose and ladder testing?
- A record for each hose length and ladder with its ID, date in service, each test date and result, repairs, and the date it was removed from service.
- Can our own crews test hose?
- Many departments test hose in-house with a hose testing machine and trained members, following the standard's procedure. Ladder testing is often done by a certified testing company.