Daily and weekly apparatus checks on a phone
Each engine, tanker and brush truck gets its check on the phone: fluids, tires, lights, warning lights and siren, air pressure, pump engagement, tank level, generator and a compartment-by-compartment equipment inventory. Career crews do it at shift change; many volunteer departments do it weekly. Each item is marked pass, warning or fail with a photo, and the completed check is saved on that apparatus with who did it and when.
Fire apparatus daily truck check and NFPA 1911 inspection
Apparatus service by engine hours and miles, and the annual pump test
Set each apparatus's oil and filter service by engine hours or miles, whichever comes first, and its annual pump service test (NFPA 1911) as a yearly schedule with the test checklist attached. When the maintenance officer enters new readings, or the date comes up, Dovient Lite opens the work order and assigns it to the people set on the schedule.

Members report problems from their phone
A member finds a scene light out on Engine 2 after a call. They pick the apparatus in the app, describe the problem, add a photo and mark it a breakdown if the truck can't respond. The maintenance officer is notified, turns the report into a work order, and the member can see when it's fixed.

Filters, bulbs and fittings on the shelf
Keep oil and fuel filters, wiper blades, warning light heads, tires, hose gaskets and spanner wrenches in the parts list with a minimum quantity for each. Parts used on a repair come off stock and add to that apparatus's cost, and anything below its minimum is marked low stock.

SCBA inspections, flow tests and cylinder hydro dates
Each SCBA pack and cylinder is an asset. The monthly inspection that OSHA 1910.134(h)(3) requires is a phone checklist (facepiece, harness, regulator, alarm, cylinder pressure), the annual flow test (NFPA 1852) is a yearly schedule, and each cylinder's hydrostatic test runs on its own date, typically every five years for composite cylinders. The pack's record shows every inspection, test and repair.
SCBA inspection checklistAnnual hose, ground ladder and turnout gear testing
Fire hose gets its annual service test (NFPA 1962), ground ladders their annual service test (NFPA 1932), and turnout gear its yearly advanced inspection, with advanced cleaning at least twice a year (NFPA 1851). Each is a yearly work order with a checklist listing every hose length, ladder or set of gear, marked pass or fail. The completed test exports as a PDF for your records, the ISO review or your insurer. NFPA has folded these standards into combined ones (1930 for hose and ladders, 1850 for gear and SCBA, 1910 for apparatus), so follow the edition your jurisdiction has adopted.
Fire hose and ground ladder testing recordsStation repairs and equipment in one list
Bay doors, the exhaust capture system, the station generator, the air compressor and cascade, and extinguishers are assets with their own schedules. Every repair, on the station or the apparatus, is a work order showing who reported it, who is on it, the photos and the status. A truck out of service is marked down, and overdue work shows on the dashboard.
Fire station and equipment inspection checklistWhat each apparatus costs, for the budget and the board
Each apparatus record holds its readings, every check, repair, part and outside shop charge. The dashboard counts breakdowns and downtime, shows MTTR and MTBF, and lists the apparatus that fail most often. That is the record the chief brings to the board or town council when asking to replace a truck.
How setup works
- 1
Add your apparatus and equipment
Import your apparatus, SCBA, hose and station equipment from a spreadsheet (CSV or Excel) or add them one at a time.
- 2
Set checks and testing schedules
Choose the truck check for each apparatus, its service intervals in hours or miles, and the yearly pump, SCBA, hose and ladder tests.
- 3
Invite your members
They install the app and sign in. Members see the checks due; the maintenance officer sees every open repair.
Set up Dovient Lite with us
Tell us how many apparatus you run. We'll go through your truck checks and testing schedules with you and set up your account.
Prefer to start on your own? Start with Dovient Lite
Fire department checklists and guides
All templates- Compliance

Fire departments
Fire hose & ground ladder testing records
- Template

Fire departments
SCBA inspection checklist
- Template

Fire departments
Fire station & equipment inspection checklist
- Compliance

Fire departments
Turnout gear inspection (NFPA 1851)
- Template

Fire departments
Fire apparatus daily truck check & NFPA 1911 inspection
Questions
What is fire department fleet maintenance software?
Software that keeps apparatus checks, scheduled service, equipment tests and repairs in one record. Dovient Lite does this for small and volunteer departments: truck checks on a phone, service by engine hours, miles or date, and a full history for each apparatus, SCBA pack and piece of station equipment.
Can members do truck checks on a phone or tablet?
Yes. A member opens the apparatus's checklist in the app, marks each item pass, warning or fail, types notes and attaches photos. The check is saved on the apparatus with their name and the time.
What does NFPA 1911 require for pump testing?
NFPA 1911 calls for a pump service test at least once a year and after major pump repair, checking that the pump still delivers its rated performance. NFPA has been folding 1911 and several related standards into combined documents (NFPA 1910 for apparatus), so follow the edition your department or state has adopted.
How often do SCBA need to be inspected?
OSHA 1910.134(h)(3) requires SCBA to be inspected monthly, and NFPA 1852 adds an inspection after each use and an annual flow test by a trained technician. Cylinders also need a hydrostatic test on the interval marked on them, typically every five years for composite cylinders.
How often do fire hose and ground ladders need testing?
Attack hose gets a service test every year under NFPA 1962, and after it's repaired or run over. Ground ladders get an annual service test under NFPA 1932, and after any event that could damage them.
Does it handle incident reports, training hours or staffing?
No. Dovient Lite covers apparatus, equipment and station maintenance. Keep incident reporting, training records and scheduling in your records management system.
Does it remind members before a test is due?
Not before. Dovient Lite opens the work order when a test or service comes due by date, hours or miles, and assigns it to the people set on the schedule. Anything not done on time shows as overdue on the dashboard.
Can I show the board what each apparatus costs to keep running?
Yes. Labor, parts and outside shop charges on each work order add to that apparatus's cost, and a cost-by-asset report shows the year's spending for each truck.
What OSHA requirements and regulations apply to fire department equipment?
OSHA 1910.134 sets the SCBA inspection rules for career departments, and state-plan states apply it to public employees. The fire service requirements most departments adopt come from NFPA: apparatus (NFPA 1910, formerly 1911), SCBA (NFPA 1852), hose (NFPA 1962) and turnout gear (NFPA 1851). Station fire protection maintenance (extinguishers, alarms, sprinklers) follows the fire code. Dovient Lite keeps the log of each inspection and test per piece of equipment.
How much does Dovient Lite cost?
Plans and prices are on the Dovient Lite pricing page: dovient.com/lite/pricing.
Reviewed
Apparatus, SCBA and hose ready for the next call
