SCBA inspection checklist

An SCBA checklist for fire departments, based on what OSHA 1910.134 requires each month and after each use, plus the annual flow test and cylinder hydrostatic test dates to track.

What OSHA requires

Under OSHA's respiratory protection standard, respirators kept for emergency use must be inspected at least monthly, following the manufacturer's recommendations, and checked for proper function before and after each use (29 CFR 1910.134(h)(3)(i)(B)). SCBA must be inspected monthly in any case, cylinders kept fully charged and recharged when pressure falls to 90% of the manufacturer's recommended level, and the regulator and warning devices checked to make sure they work (1910.134(h)(3)(iii)).

Each inspection must cover function, tightness of connections and the condition of the facepiece, head straps, valves and hoses, and the elastomeric parts for pliability and signs of wear (1910.134(h)(3)(ii)). In states with their own OSHA plan, the state rule applies and is at least as strict.

Records you must keep

  • For each emergency-use SCBA: the date of inspection, the name or signature of the inspector, the findings, any remedial action, and the serial number or other ID (1910.134(h)(3)(iv)(A)).
  • Keep it on a tag or label with the SCBA or its storage compartment, or in paper or electronic inspection reports, until the next inspection replaces it.
  • A pack that fails must be removed from service. Regulators, reducing valves and alarms may only be adjusted or repaired by the manufacturer or a technician trained by the manufacturer (1910.134(h)(4)).

Other SCBA dates to track

  • Daily or each shift: most departments check the SCBA on each riding position at shift change.
  • Yearly: flow test on a calibrated test bench by a manufacturer-trained technician, required by NFPA 1852, which is now part of NFPA 1850.
  • Cylinder hydrostatic test: on the interval in the cylinder's DOT special permit, commonly every 5 years for carbon fiber cylinders.
  • Cylinder service life: composite cylinders are commonly limited to 15 years from the manufacture date. Check the label and the permit.
  • Fit testing: each firefighter's tight-fitting facepiece fit test at least yearly under 1910.134(f).

SCBA inspection

Monthly, and before and after each use

Cylinder

  • Cylinder at least 90% of rated pressure
  • Hydrostatic test date current
  • No cuts, gouges, burns or exposed fibers
  • Valve and gauge undamaged, valve opens freely

Straps and backframe

  • Straps, buckles and backframe undamaged
  • Cylinder band latched and secure

Regulator and hoses

  • High and low pressure hoses not cracked
  • Connections tight, no audible leaks
  • Regulator and bypass work
  • Cylinder and remote gauges read within limits

Facepiece

  • Lens clean, not cracked or scratched
  • Head straps and rubber pliable, no tears
  • Exhalation valve clean and seating
  • Facepiece seals on negative pressure check

Alarms

  • Low air alarm sounds
  • PASS device sounds in alarm and motion mode
  • Heads-up display lights work

Inspected by, date and notes go at the bottom of the printed sheet.

Run it in Dovient Lite

Add each SCBA pack and each cylinder as an asset with its serial number and station, and print a QR label for it. Set a monthly schedule with this checklist attached and a yearly schedule for the flow test, and record each cylinder's hydrostatic test as its own scheduled work order. The firefighter marks each item pass, warning or fail on the phone, and the completed inspection stays on the pack's record with who did it and when, ready to export as PDF.

Start with Dovient Lite

Sources

Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.

Questions

How often does OSHA require SCBA inspections?
At least monthly, and before and after each use. Cylinders must be recharged when they fall to 90% of the manufacturer's recommended pressure.
What records do I need for SCBA inspections?
For each pack: date, inspector, findings, remedial action and serial number, on a tag with the unit or in paper or electronic reports.
How often are SCBA cylinders hydrostatically tested?
On the interval in the cylinder's DOT special permit, commonly every 5 years for carbon fiber composite cylinders. The permit and the cylinder label are the authority.
Who can repair an SCBA regulator?
Only the manufacturer or a technician trained by the manufacturer, using NIOSH-approved parts.