The rules behind a fire department inspection
OSHA's respiratory protection standard requires SCBA to be inspected monthly and checked before and after each use, with cylinders recharged when pressure falls to 90% of the manufacturer's recommended level (29 CFR 1910.134(h)(3)). OSHA covers private and federal employers directly; in state-plan states the same rules apply to public fire departments.
Most of the fire service's equipment care comes from NFPA standards your department or state adopts. NFPA has been combining them: NFPA 1850 (2026) now covers the selection, care and maintenance of turnout gear and SCBA that were in NFPA 1851 and 1852, NFPA 1930 covers ground ladders, hose, tools and other equipment from NFPA 1932, 1962 and others, and NFPA 1910 covers apparatus inspection and testing from NFPA 1911. Use the edition your jurisdiction has adopted.
How often to check what
- Each shift or daily: SCBA on the apparatus, radios, thermal imager, and the station walk-through.
- After each use: SCBA, turnout gear, tools and hose put back in service.
- Weekly: generator test, exhaust capture system, bay doors and sensors, small engines started.
- Monthly: SCBA monthly inspection, extinguishers, emergency lights, eyewash, AED, first aid supplies.
- Yearly: hose and ladder service tests, SCBA flow tests, turnout gear advanced inspection, pump test on the apparatus.
Records to keep
Keep a record per item: each SCBA pack and cylinder, each set of gear, each ladder and hose length, each tool. The record shows the date, who did the check, the result, and any repair or removal from service. When something fails, tag it out of service, record why, and record when it came back. These records answer the questions an ISO review, an insurer or an injury investigation will ask.
Fire station and equipment inspection
Daily walk, with monthly items marked
SCBA
- Cylinder at least 90% of rated pressure
- Facepiece clean, no cracks, straps intact
- Regulator and low-air alarm working
- PASS device sounds when tested
- Hydrostatic test date within limit
Turnout gear
- Gear clean, no rips, burns or contamination
- Reflective trim intact
- Stored out of sunlight and off the apparatus floor
- Helmet shell and suspension undamaged
Tools and small equipment
- Radios charged and working
- Thermal imager charged and working
- Saws and generators start and run
- Extrication tools no leaks, blades undamaged
- Flashlights and hand lights working
Station building
- Bay doors open, close and reverse on contact
- Vehicle exhaust system connects and runs
- Extinguishers in place, checked this month
- Exit signs and emergency lights working
- Eyewash and AED ready
Living areas
- Smoke and CO alarms working
- Kitchen clean, hood filters clean
- Gear and decon areas kept separate from living areas
Inspected by, date and notes go at the bottom of the printed sheet.
Run it in Dovient Lite
Add each SCBA pack, cylinder, set of gear, tool and the station itself as assets, and print QR labels for them. Attach this checklist to a daily schedule and the SCBA monthly inspection to a monthly one, so a work order opens when each is due. Firefighters mark each item pass, warning or fail on the phone with photos, and the result stays on each item's record with who did it and when.
Start with Dovient LiteSources
- OSHA, Respiratory protection, 29 CFR 1910.134(h)(3)
- NFPA 1850, care and maintenance of turnout gear and SCBA
- NFPA 1930, fire service equipment, hose and ground ladders
Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.
Questions
- How often must SCBA be inspected?
- OSHA requires a monthly inspection and a check before and after each use (29 CFR 1910.134(h)(3)). Many departments also check SCBA at the start of every shift.
- What records should a fire station keep?
- A record for each SCBA, set of gear, ladder, hose length and tool: date, who checked it, the result, and any repair or removal from service.
- Which NFPA standards cover station equipment?
- NFPA 1850 for turnout gear and SCBA care, NFPA 1930 for hose, ladders and tools, and NFPA 1910 for apparatus. These replaced older standards such as 1851, 1852, 1962, 1932 and 1911.
- How often should the station walk-through be done?
- Daily or at each shift change is common, with monthly items such as extinguishers and emergency lights added once a month.