Gas station & c-store daily maintenance checklist

A daily gas station checklist for the forecourt and the store, done at opening or shift change, with the rules behind the fuel and safety items and the monthly UST checks that sit alongside it.

What the rules require

Most of the daily list is good practice, but several items come from code. Fire codes based on NFPA 30A require a clearly identified emergency shutoff for the dispensers, and fire extinguishers on the forecourt. OSHA requires monthly visual checks of extinguishers (29 CFR 1910.157(e)) and clear exit routes in the store. Your state weights and measures office tests and seals dispensers.

The federal UST rules add a walkthrough every 30 days: spill buckets checked for damage, liquid and debris, fill caps secure, and the tank gauge on with no alarms (40 CFR 280.36). That walkthrough has its own record, kept for one year. The daily check below is where a store manager spots problems between walkthroughs.

Convenience store daily and shift checklist

Run the checklist at opening, and repeat the forecourt and restroom items at each shift change on busy sites. Anything that fails gets a photo and a repair request, and a dispenser with a leak or a broken nozzle is bagged and taken out of service until it is fixed.

Weekly and monthly items

  • Weekly: check dispenser filters for slow flow, clean canopy lights and signs, and test the emergency shutoff if your procedure calls for it.
  • Monthly: UST walkthrough (40 CFR 280.36), fire extinguisher inspection, hoses and breakaways inspected closely, ice machine and cooler coils cleaned as needed.
  • Yearly: UST release detection equipment test, extinguisher maintenance, and the dispenser checks your service company recommends.

Records to keep

Keep the daily checklist, the monthly UST walkthroughs for one year, tank gauge results, contractor test reports and every dispenser repair. A state tank inspector, a weights and measures inspector and your insurer will each ask for part of this.

Gas station and c-store daily check

Daily at opening, forecourt items each shift

Fuel dispensers

  • Hoses not cracked, kinked or leaking
  • Nozzles shut off and hang up properly
  • Breakaways connected, not separated
  • Card readers and screens working
  • No fuel staining under dispensers

Forecourt safety

  • Emergency shutoff clear and labeled
  • Fire extinguishers in place and charged
  • Spill kit stocked
  • Tank gauge on, no alarms
  • Spill bucket lids closed

Lot and building outside

  • Canopy and lot lights working
  • Trash cans emptied, lot swept
  • Air and water machine working
  • No trip hazards or broken curbs

Store

  • Coolers and freezers holding temperature
  • Ice machine working, bin clean
  • Coffee and fountain equipment working
  • Exits clear, exit doors open from inside

Restrooms

  • Clean and stocked
  • Toilets and sinks working, no leaks
  • Lights and locks working

Inspected by, date and notes go at the bottom of the printed sheet.

Run it in Dovient Lite

Add each dispenser, the tank system, coolers and the ice machine as assets, and set this checklist as a daily schedule and the UST walkthrough as a monthly one. A work order opens each day; the manager marks each item pass, warning or fail on the phone with a photo of anything wrong. Staff can report a broken pump as a service request and mark it a breakdown, the assigned people are notified, and the request becomes a work order with the repair cost on that dispenser's record.

Start with Dovient Lite

Sources

Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.

Questions

What should a gas station daily checklist include?
Dispenser hoses, nozzles and breakaways, the emergency shutoff, extinguishers, spill kit, tank gauge alarms, lot lighting, coolers, the ice machine, exits and restrooms.
How often does a gas station need to inspect its tanks?
Federal rules require a walkthrough every 30 days for spill buckets and release detection equipment, and once a year for sumps and handheld equipment. Many states add their own requirements.
What records should a convenience store keep for maintenance?
Daily checklists, monthly UST walkthroughs for one year, tank gauge results, contractor test reports and dispenser repairs.