What the rules require
The health inspector works from your state's version of the FDA Food Code. It requires cold food held at 41°F or below (3-501.16), equipment kept in good repair (4-501.11), and ice machines and other equipment cleaned at the frequency the manufacturer specifies (4-602.11). Inspectors look at gaskets, thermometers, ice machine interiors and dish machine temperatures.
The fire marshal works from NFPA 96. The hood and exhaust system must be inspected for grease buildup on a schedule set by your cooking volume: monthly for solid fuel, quarterly for high-volume cooking such as 24-hour, charbroil or wok, semiannually for moderate volume, and yearly for low volume. The hood fire suppression system is inspected by a licensed contractor every six months. Your city or county can set stricter terms, so check with the local authority.
Restaurant maintenance schedule
- Daily: walk-in and reach-in temperatures, hood filters wiped, fryer oil and dish machine checked.
- Weekly: hood filters run through the dish machine or soaked, fryer boiled out, drains cleared.
- Monthly: this checklist across all equipment.
- Every 6 months, or as the maker specifies: ice machine cleaned and sanitized, water filters changed, hood suppression inspected.
- On the NFPA 96 schedule for your volume: hood and duct inspected and cleaned by a contractor.
- Yearly: refrigeration service, gas line and connector check, extinguisher maintenance.
Records to keep
Keep the dated monthly checklist, every contractor report (hood cleaning, suppression, refrigeration, grease trap pump-outs) and the repair history for each unit. The fire marshal asks for the hood cleaning and suppression reports; the health inspector may ask how often the ice machine is cleaned. A history per unit also tells you when a 15-year-old walk-in compressor is costing more than it is worth.
Commercial kitchen equipment maintenance
Monthly
Walk-ins and reach-ins
- Holding at 41°F or below (freezers at 0°F)
- Door gaskets sealed, not torn or loose
- Doors close on their own, hinges tight
- Condenser coils clean, fans running
- Evaporator drain line clear, no ice buildup
- Thermometer present and reading correctly
Cooking line
- Burners light and flames burn blue
- Gas connectors not kinked, restraint cable on
- Fryer thermostats hold set temperature
- Oven doors seal, thermostats calibrated
- Griddle and charbroiler surfaces intact
Hood and fire safety
- Hood filters in place and clean
- Exhaust fan running, belt in good shape
- Suppression tag current (within 6 months)
- Nozzle caps in place over the appliances
- Class K extinguisher charged and mounted
Dish machine and ice machine
- Wash and rinse temperatures reach spec
- Sanitizer or chemical feed working
- Spray arms clear, curtains in place
- Ice machine interior clean, no slime or mold
- Water filter changed on schedule
Plumbing
- Floor drains flow, no standing water
- Hand sinks have hot water, soap and towels
- No leaks under sinks or at the dish machine
- Grease trap pumped on schedule
Inspected by, date and notes go at the bottom of the printed sheet.
Run it in Dovient Lite
Add each walk-in, fryer, oven, dish machine and ice machine as an asset, and set a monthly schedule with this checklist, plus dated schedules for ice machine cleaning and contractor hood service. A work order opens when each is due, and the cook or manager marks each item pass, warning or fail on the phone with a photo of anything wrong. Attach the contractor's report to the work order, and export the completed checks as a PDF for the health inspector or fire marshal.
Start with Dovient LiteSources
- FDA Food Code 2022, 3-501.16, 4-501.11, 4-602.11
- NFPA 96, Ventilation Control and Fire Protection of Commercial Cooking Operations, Inspection for grease buildup
Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.
Questions
- How often should restaurant kitchen equipment be maintained?
- Do daily and weekly cleaning checks, a monthly equipment checklist like this one, and contractor service on the hood, suppression system, refrigeration and ice machine at the intervals your code and the manufacturer set.
- How often does a restaurant hood need cleaning?
- NFPA 96 sets the inspection interval by cooking volume, from monthly for solid fuel to yearly for low volume. When the inspection finds grease buildup, the system is cleaned. Your fire marshal may set a stricter schedule.
- What records do I need for the health inspector and fire marshal?
- Keep hood cleaning and suppression inspection reports, refrigeration temperature records, ice machine cleaning dates and grease trap pump-out receipts. A dated equipment checklist shows the kitchen is kept in good repair.
- How often should an ice machine be cleaned?
- The FDA Food Code says at the frequency the manufacturer specifies. Many manufacturers call for cleaning and sanitizing every six months, more often in a hot or dusty kitchen.