Dovient

Template · Compliance

Restaurant health inspection checklist

A self-inspection checklist built on what health inspectors look at during restaurant inspections, with the FDA Food Code rules behind it. Walk it before every shift change or weekly, on paper or on a phone.

Who inspects restaurants and what rules they use

Restaurant inspections are done by your state or local health department, not by the FDA. Most states base their rules on the FDA Food Code, a model code that each state adopts in its own edition and sometimes changes. Florida is an example of a state agency doing the work: the Division of Hotels and Restaurants inspects most restaurants there. In other states it is the county or city health department.

How often you are inspected depends on your jurisdiction. Many health departments set the frequency by risk, so a full-menu kitchen that cools and reheats food is visited more often than a coffee counter. Inspection reports and scores are public records in most places, and many departments post them online.

OSHA rules apply too, but they cover your employees, not the food: wet floors, burns, cuts, and chemical labels and safety data sheets under the hazard communication standard.

What inspectors look at first

  • Temperatures: cold food held at 41°F or below and hot food at 135°F or above (Food Code 3-501.16).
  • Date marking: ready-to-eat food that needs refrigeration labeled and used within 7 days at 41°F (3-501.17).
  • Handwashing: sinks stocked with soap and paper towels, not blocked, used only for hands.
  • A certified food protection manager on staff (2-102.12) and a person in charge on every shift.
  • Cross-contamination: raw meat stored below ready-to-eat food, clean cutting boards and utensils.
  • Sanitizing: dish machine or sanitizer buckets at the right concentration, with test strips on hand.
  • Pests, building condition, and equipment in good repair.

How often to run the checklist and what to keep

Most managers run a short opening and closing check every day and the full checklist below once a week. Run it again the day after any repair to a cooler, dish machine or hand sink. The Food Code does not require a fixed self-inspection log for most kitchens, but your health department may ask for temperature logs, pest control reports and hood cleaning records, and a record of your own checks shows the inspector that problems get found and fixed.

Keep pest control service reports, hood and suppression service tags, grease trap pumping records, and your manager certificates where you can find them on the day of the visit.

Restaurant health inspection self-check

Weekly, plus after repairs

Temperatures

  • Walk-in and reach-ins at 41°F or below
  • Hot holding at 135°F or above
  • Calibrated probe thermometer on the line
  • Food cooling in shallow pans, uncovered

Storage and labeling

  • Ready-to-eat food date marked, within 7 days
  • Raw meat stored below ready-to-eat food
  • Food stored 6 inches off the floor
  • Chemicals stored away from food and labeled

Handwashing and sanitizing

  • Hand sinks stocked with soap and towels
  • Hand sinks clear and used only for hands
  • Sanitizer at the right concentration
  • Dish machine reaching its sanitizing cycle

Facility and equipment

  • No signs of pests, doors and screens closed
  • Floors, walls and ceilings clean and intact
  • Gaskets on coolers clean and not torn
  • Hood filters clean, service tag current
  • No leaks under sinks or at the grease trap

People and paperwork

  • Certified food protection manager on staff
  • Person in charge named for the shift
  • Staff wearing hair restraints, no jewelry
  • Pest control report from the last visit on file

Inspected by, date and notes go at the bottom of the printed sheet.

Run it in Dovient Lite

Add the kitchen as a location and the coolers, hood, dish machine and hand sinks as assets. Set a weekly schedule with this checklist attached; a work order opens each week, and the manager marks each item pass, warning or fail on the phone with a photo of anything wrong. Cooks report a broken cooler or leaking sink from the phone, and the completed checklists and repairs export as a PDF for the health inspector.

Start with Dovient Lite

Sources

Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.

Questions

How often do restaurants get health inspections?
It depends on your state or local health department. Many set the frequency by risk, so kitchens that cook, cool and reheat food are inspected more often than low-risk operations.
How often should a restaurant do its own inspection?
A short check at opening and closing every day, and the full checklist once a week, is a common routine. Run it again after any repair to refrigeration or sinks.
What records do I need for a health inspection?
Your manager certificate, pest control reports, and any logs your health department requires, such as cooling or temperature logs. Hood cleaning and suppression service records are checked by the fire marshal and sometimes the health inspector.
Are restaurant inspection reports public?
In most states and cities, yes. Many health departments post inspection reports and scores online.