What the rules require
There is no single federal dock inspection rule. Several codes and agencies apply. OSHA requires employers to inspect walking-working surfaces regularly and as necessary and keep them in safe condition (29 CFR 1910.22(d)), which covers docks your staff work on. Most fire marshals enforce NFPA 303, the fire protection standard for marinas and boatyards, and electrical inspectors enforce Article 555 of the National Electrical Code, which requires ground-fault protection on marina and dock power.
Public marinas built or altered since 2012 must also meet the accessible boating facility rules in the 2010 ADA Standards (sections 235 and 1003), including gangways and accessible boat slips. Dock permits and repair rules come from your state or the waterway authority, such as a state DNR or environmental agency, the Army Corps of Engineers, or TVA on its reservoirs. Check your permit for any inspection terms.
How often to inspect
- Monthly in season: dock walk with the checklist below.
- After every storm, high water or ice event: full walk before boaters return to the docks.
- Before the season opens and after it closes: full walk, plus pedestal and electrical checks.
- Yearly, or as your insurer asks: underwater and structural inspection by a marine contractor or engineer for pilings, anchors and float connections.
Records to keep
Keep the date, who inspected, the dock and slip, each finding with a photo, and the repair that followed. Insurers and fire marshals ask for this after an injury or fire, and a dated record of inspections and repairs is your best answer to a slip-and-fall claim.
Dock and pier inspection
Monthly in season, and after every storm
Decking and walkways
- Boards solid, none cracked, rotted or missing
- Fasteners flush, no raised nails or screws
- Surface not slippery, no algae or ice
- Gangway hinges, rollers and transition plates work
- Handrails and guardrails secure
Structure
- Pilings straight, no splits or heavy rot
- Floats level, none sinking or damaged
- Float connections and chains secure
- Anchors and pile guides holding position
Cleats and mooring
- Cleats tight, not cracked
- Bumpers and dock edging in place
- Finger piers firm, not loose at the joint
Electrical and water
- Pedestals secure, covers closed
- Ground-fault protection tests OK
- No heat marks or damaged receptacles
- Cords and cables off the deck, not in water
- Water lines and hose bibs not leaking
Safety equipment
- Life rings in place with line attached
- Ladders secure and reach into the water
- Fire extinguishers charged and tagged
- Lighting works along the dock
- Warning and no-swimming signs readable
Inspected by, date and notes go at the bottom of the printed sheet.
Run it in Dovient Lite
Add each dock, gangway and power pedestal as an asset with its location, and set this checklist as a monthly schedule. A work order opens when it is due; the dock hand marks each item pass, warning or fail on the phone and adds a photo of anything damaged, and the completed check stays on that dock's record. After a storm, staff can report damage as a service request with a photo, and the request becomes the repair work order.
Start with Dovient LiteSources
- OSHA, Walking-working surfaces, 29 CFR 1910.22(d)
- NFPA 303, Fire Protection Standard for Marinas and Boatyards
- NFPA 70, National Electrical Code, Article 555
- U.S. Access Board, Guide to the ADA Standards, Boating facilities, 2010 ADA Standards 235 and 1003
Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.
Questions
- How often should a marina inspect its docks?
- Monthly in season, after every storm or high water, and before and after the season. Have pilings, anchors and float connections inspected by a marine contractor yearly or as your insurer requires.
- What does OSHA require for docks?
- OSHA requires walking-working surfaces your employees use, including docks, to be inspected regularly and kept in safe condition. Electrical and fire rules come from the NEC and NFPA 303.
- Do dock pedestals need ground-fault protection?
- Yes. Article 555 of the National Electrical Code requires ground-fault protection for marina and dock power. Test it as the manufacturer directs and after any storm.
- What records should a marina keep for dock inspections?
- The date, inspector, dock, findings with photos and the repairs that followed. Keep them for insurers, fire marshals and any injury claim.