Marina maintenance software

Docks, pedestals and lifts inspected through the season

Dock hands walk the docks and test shore-power pedestals on a phone, boat lifts, the travel lift and forklifts are serviced on schedule, and the fuel dock's spill and fire equipment is checked and recorded.

Boats tied up along the docks at a marina

Dock inspections and shore-power pedestal checks

A dock hand walks each dock monthly and after storms with the checklist on the phone: decking and fasteners, cleats, pilings and float chains, gangway hinges and rollers, ladders, life rings and lighting. Each pedestal gets its ground-fault test, cord and receptacle check and a look for heat marks, since NFPA 303 and Article 555 of the National Electrical Code require ground-fault protection on marina power. Anything marked fail gets a photo, and the dockmaster opens the repair.

Dock and pier inspection checklist
Dovient Lite checklist on a work order (technician view): Dock inspections and shore-power pedestal checks for a marina

Boat lift, travel lift and forklift maintenance

Each boat lift gets its cable, sheave, gearbox and motor checks on dates, with grease points done before the season. The travel lift and the dry stack forklift run on engine hours (oil and hydraulic service every 250 hours, for example), and the forklift's daily pre-use examination required by OSHA 1910.178(q)(7) is a phone checklist. When a reading or date comes due, the work order opens with its checklist attached.

Boat lift maintenance and inspection
Dovient Lite preventive maintenance schedule: Boat lift, travel lift and forklift maintenance for a marina

Dock staff report problems from the phone

A boater calls the office about no power at C-14, or a dock hand finds a split board on B dock. Staff pick the pedestal or dock in the app, describe the problem, add a photo and mark it a breakdown if it's unsafe. The maintenance lead is notified, turns the report into a work order, and the person who reported it can see when it's fixed.

Dovient Lite report a problem from the phone, with photo and breakdown flag: Dock staff report problems from the phone for a marina

Lift cables, zincs and pedestal parts on the shelf

Keep lift cables, zinc anodes, cleats, dock bumpers, pedestal breakers and receptacles, absorbent pads and hydraulic fluid in the parts list with a minimum quantity for each. Parts used on a repair come off stock and add to that asset's cost, and anything below its minimum is marked low stock.

Dovient Lite parts inventory with stock levels and low-stock flags: Lift cables, zincs and pedestal parts on the shelf for a marina

Every repair in one list, across every dock

Each repair is a work order: who reported it, who is on it, the photos, the notes and the status. The dockmaster assigns jobs from the office, the yard crew updates them from a phone, and overdue work shows on the dashboard. A lift or pedestal that is out of service is marked down, so the office knows before assigning a slip.

Fuel dock spill and fire equipment checks

The fuel dock gets its own monthly checklist: fire extinguishers (NFPA 10), spill kit and absorbent booms stocked, emergency fuel shutoff marked and working, hoses, nozzles and breakaways, and no-smoking signs. If your aboveground fuel storage puts you under the EPA's SPCC rule (40 CFR 112), the tank inspections your plan lists can be schedules too. Completed checks export as a PDF for the fire marshal or your insurer.

Marina maintenance and safety checklist

Each lift's history and repair cost

Every boat lift, pedestal, dock section and machine has a record with its schedule, every inspection and repair, the parts used and what it cost, including outside contractors such as the electrician or the lift service company. The dashboard lists the assets that break down most often, so you know which lifts to rebuild before next season.

QR codes on pedestals and lifts (optional)

Print a QR label for each pedestal and lift from Dovient Lite. A dock hand scans it with the app and lands on that asset's record: checks due, open repairs and its history. Useful once you have more pedestals than anyone wants to pick from a list.

How setup works

  1. 1

    Add your docks and equipment

    Import your docks, pedestals, lifts and machines from a spreadsheet (CSV or Excel) or add them one at a time.

  2. 2

    Set inspections and schedules

    Choose the dock, pedestal and fuel dock checklists, and the service intervals for lifts and machines in engine hours or days.

  3. 3

    Invite your dock hands and yard crew

    They install the app and sign in. Dock hands see the day's checks; the yard crew sees the repairs assigned to them.

Set up Dovient Lite with us

Tell us how many slips you have. We'll go through your dock inspections and lift schedules with you and set up your account.

Prefer to start on your own? Start with Dovient Lite

Marina checklists and guides

All templates

Questions

What is marine maintenance software?

Software that keeps a marina's dock inspections, scheduled equipment service and repairs in one record. Dovient Lite does this for small teams: dock and pedestal checks on a phone, lifts and machines serviced by date or engine hours, and a full history for each asset.

Is this marina management software for slips and billing?

No. Dovient Lite doesn't handle reservations, slip assignments, boater accounts or billing. Keep your marina management software for those and use Dovient Lite for the docks, lifts and equipment.

How should shore-power pedestals be checked?

NFPA 303 and Article 555 of the National Electrical Code (NFPA 70) require ground-fault protection on marina power to reduce the risk of electric shock drowning. Test the ground-fault devices on the schedule the manufacturer or your electrician sets, and look over cords, receptacles and covers for damage and heat marks. Each pedestal can have that checklist on a schedule in Dovient Lite.

What marine compliance records does a fuel dock need?

Fire extinguishers need a monthly inspection and annual maintenance (NFPA 10), and NFPA 30A covers marine fuel dispensing. If you store more than 1,320 gallons of oil in aboveground containers, the EPA's SPCC rule (40 CFR 112) requires a plan with inspections, and records of them kept for three years. Your fire marshal may ask for more; completed checks export as a PDF.

Can boaters report a problem by scanning a QR code?

No. Requests need a Dovient Lite login, so boaters call or tell the office and staff enter the request from their phone. QR labels in Dovient Lite open the asset record for signed-in staff.

Can I schedule boat lift maintenance?

Yes. Boat lift checks run on dates (monthly, before the season, yearly), and the travel lift and forklifts can run on engine hours, dates, or whichever comes first. The work order opens when it's due, with its checklist attached.

Does it alert me if a pedestal fails its test?

Not automatically. A failed item is saved with its photo on the pedestal's record, and the dock hand or dockmaster opens the repair work order. Open and overdue repairs show on the dashboard.

Can I track repair costs per lift or dock?

Yes. Labor, parts and outside contractor charges on each work order add to that asset's cost, and its record shows what it has cost this year.

How much does Dovient Lite cost?

Plans and prices are on the Dovient Lite pricing page: dovient.com/lite/pricing.

Reviewed

Docks, pedestals and lifts inspected through the season