Lockout/tagout (LOTO) procedure template

What OSHA's lockout tagout rule asks of a machine shop, a procedure outline you can fill in for each machine, and a checklist for the yearly inspection of each procedure.

What lockout/tagout means

Lockout/tagout (LOTO) is how you keep a machine from starting or releasing energy while someone is servicing it. The person doing the work shuts the machine down, isolates every energy source (electric, air, hydraulic, gravity, springs), puts their own lock on each isolation point, bleeds off stored energy and then tries to start it to prove it is dead.

OSHA's rule is 29 CFR 1910.147, the control of hazardous energy. It applies to servicing and maintenance where an unexpected startup or release of energy could hurt someone: clearing a jam in a press, changing tooling, working inside a CNC enclosure, replacing a belt on a saw.

What the rule requires

  • A written energy control program: procedures, training and periodic inspections (1910.147(c)(1)).
  • A written lockout tagout procedure for each machine, except for the narrow single-energy-source exception in (c)(4)(i).
  • Locks and tags that are only used for energy control, standardized in the shop, durable, and identify who put them on ((c)(5)).
  • An inspection of each procedure at least once a year by an authorized employee who is not using that procedure ((c)(6)).
  • Training for authorized and affected employees, retraining when jobs, machines or procedures change, and a training certification with names and dates ((c)(7)).

Lockout tagout procedure template

Section (c)(4)(ii) says each procedure must state its intended use and give specific steps for shutting down, isolating, blocking and securing the machine, for placing and removing locks and tags, and for testing that the energy is under control. A one-page procedure per machine usually has these parts:

  1. Machine name, asset number, location, and who is authorized to lock it out.
  2. Energy sources: each one with its type, magnitude (for example 480 V, 90 psi) and isolation point.
  3. Preparation and shutdown: notify affected employees, stop the machine with its normal controls.
  4. Isolation: open each disconnect, close and bleed each valve, and lock and tag each point.
  5. Stored energy: bleed air and hydraulic pressure, block raised parts, let flywheels stop, discharge capacitors.
  6. Verification: clear people away, press start, check with a meter where needed, return controls to off.
  7. Release: tools out, guards back on, people clear, affected employees told, each person removes their own lock.

The yearly inspection and the records to keep

Under 1910.147(c)(6)(i), an authorized employee other than the ones using the procedure watches it being done, corrects anything wrong, and reviews each person's responsibilities with them. The employer then certifies the inspection with the machine, the date, the employees included and the person who did the inspection ((c)(6)(ii)).

When OSHA visits after a hand injury or a complaint, the inspector typically asks for the written program, the procedure for the machine involved, the last periodic inspection for it and the training records. Shops are often cited for generic procedures that do not list each machine's energy sources, and for missing annual inspections. Keep the procedure, the inspection certifications and training certifications on file, and update the procedure when the machine changes.

Annual lockout/tagout procedure inspection

At least once a year, for each machine procedure

Written procedure

  • Procedure on file for this machine
  • All energy sources and isolation points listed
  • Procedure matches the machine as it is today

Shutdown and isolation

  • Machine stopped with its normal controls
  • Every isolation point operated and locked
  • Each worker applied their own lock and tag
  • Locks and tags are the shop's standard devices

Stored energy and verification

  • Air, hydraulic and spring energy relieved
  • Raised parts blocked or lowered
  • Start attempted and machine did not move

Release and review

  • Tools removed and guards back in place
  • Affected employees told before restart
  • Each lock removed by the person who placed it
  • Responsibilities reviewed with each employee

Inspected by, date and notes go at the bottom of the printed sheet.

Run it in Dovient Lite

Add each machine as an asset and attach its written procedure as a file. Set a yearly schedule with the inspection checklist above; when it is due, a work order opens and the inspector marks each item pass, warning or fail on the phone, with photos of lock points. The completed checklist stays on the machine's record with who did it and when, and you can export it as a PDF for an OSHA visit.

Start with Dovient Lite

Sources

Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.

Questions

What is the difference between lockout and tagout?
Lockout puts a lock on the energy isolating device so it cannot be turned on. Tagout hangs a warning tag on it. OSHA expects lockout whenever the device can take a lock, and tagout alone only where it gives the same level of safety.
How often do lockout tagout procedures need to be inspected?
At least once a year, by an authorized employee who is not one of the people using that procedure (1910.147(c)(6)). The inspection has to be certified with the machine, date, employees and inspector.
Do I need a separate procedure for every machine?
Each machine needs a procedure that covers its specific energy sources and steps. Machines with the same energy sources and the same steps can share one procedure, but a generic shop-wide procedure that does not list the energy sources is not enough.
Who can remove a lock?
The person who put it on. OSHA allows another person to remove it only under a written procedure that confirms the worker is not at the machine, tries to reach them, and tells them before they return to work.