What HACCP is, in simple terms
HACCP stands for Hazard Analysis and Critical Control Points. You look at each step of your process, find the hazards that could make food unsafe (biological, chemical or physical), and pick the few steps where you can control them. Those steps are your critical control points (CCPs). Common examples are a cook step, a cooling step and a metal detector.
At each CCP you set a limit you can measure, such as a minimum internal temperature, check it on a schedule, write it down, and act when it is missed. The HACCP plan is the written document that lists all of this.
Who has to have a HACCP plan
Many customers and certification schemes such as SQF and BRCGS also expect a HACCP plan, even when the law does not require one.
- Meat and poultry plants inspected by USDA FSIS: HACCP is required under 9 CFR part 417.
- Seafood processors: FDA's seafood HACCP rule, 21 CFR part 123.
- Juice processors: FDA's juice HACCP rule, 21 CFR part 120.
- Most other FDA-registered food plants: a food safety plan under the preventive controls rule (21 CFR part 117). It is built the same way as HACCP but covers more types of controls, such as sanitation, allergen and supply-chain controls.
The seven principles
- Conduct a hazard analysis for each product and process step.
- Determine the critical control points.
- Set a critical limit for each CCP (for example, a temperature and time).
- Set monitoring procedures: what is checked, how, how often and by whom.
- Set corrective actions for when a limit is missed, including what happens to the product.
- Set verification procedures, such as record review and thermometer calibration.
- Keep records of monitoring, corrective actions and verification.
Records and reassessment
USDA plants must sign and date the plan, and reassess it at least once a year and whenever something changes that could affect the hazard analysis (9 CFR 417.2(d) and 417.4(a)(3)). Monitoring records are kept at least one year for slaughter and refrigerated product, and at least two years for frozen, preserved or shelf-stable product (9 CFR 417.5(e)). FDA's seafood rule uses the same one-year and two-year periods (21 CFR 123.9(b)).
An inspector or auditor will read the plan, then pull monitoring logs for a few days and check that readings were taken on schedule, that missed limits have a corrective action, that someone reviewed the records, and that the thermometers used were calibrated. Maintenance records matter too: a metal detector or a cooker that is not maintained cannot hold a critical limit.
HACCP CCP monitoring log
At the frequency set in your HACCP plan for each CCP
| Date | Time | Product / line | CCP | Critical limit | Reading | Corrective action | Initials |
|---|---|---|---|---|---|---|---|
The printed log has 10 rows per page.
Run it in Dovient Lite
Dovient Lite does not write your HACCP plan. It handles the equipment side: add each cooker, cooler, metal detector and thermometer as an asset, attach a checklist for its CCP check and calibration, and set a schedule so a work order opens when each check is due. Operators mark each item pass, warning or fail on the phone, the result stays on the asset's record with who did it and when, and completed work orders export as PDF for the auditor.
Start with Dovient LiteSources
- USDA FSIS, HACCP Systems, 9 CFR part 417
- FDA, Fish and fishery products (seafood HACCP), 21 CFR part 123
- FDA, FSMA Final Rule for Preventive Controls for Human Food, 21 CFR part 117
Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.
Questions
- Is HACCP required by law in the US?
- Yes for meat and poultry plants under USDA (9 CFR 417), seafood processors (21 CFR 123) and juice processors (21 CFR 120). Most other FDA-registered plants need a food safety plan under 21 CFR 117 instead, which follows the same logic.
- How often should a HACCP plan be reviewed?
- USDA plants must reassess the plan at least once a year and after any change that could affect the hazard analysis. Under FDA's preventive controls rule, the food safety plan is reanalyzed at least every three years and when something changes.
- How long do I keep HACCP records?
- Under the USDA and FDA seafood rules, at least one year for refrigerated product and at least two years for frozen, preserved or shelf-stable product. Your customer or certification scheme may ask for longer.
- What does a food plant need to track to stay compliant?
- CCP monitoring, corrective actions, verification such as thermometer calibration and record review, sanitation, and maintenance of the equipment that controls each hazard. Keep each record dated and initialed by the person who did it.