Dovient

Compliance

FSMA compliance & food safety plan

What FSMA compliance means for a US food plant: who needs a written food safety plan, what goes in it, how often it is reviewed, the records to keep and what FDA investigators check.

FSMA in simple terms

The FDA Food Safety Modernization Act (FSMA) shifted food safety from reacting to outbreaks to preventing them. For most food plants, the rule that matters is Preventive Controls for Human Food, codified at 21 CFR part 117. It has two main parts: current good manufacturing practices (CGMPs) in subpart B, which cover cleaning, equipment, pest control and employee hygiene, and hazard analysis and risk-based preventive controls in subpart C, which require a written food safety plan.

It applies to facilities that must register with FDA: plants that manufacture, process, pack or hold human food. Qualified facilities, which are very small by FDA's definition, have modified requirements. Plants already covered by FDA's seafood or juice HACCP rules follow those rules for the hazards they cover.

What goes in a food safety plan

The plan must be written, and a preventive controls qualified individual (PCQI) must prepare it or oversee its preparation (21 CFR 117.126). A PCQI is someone who has finished FDA-recognized training or is qualified through job experience. Under 117.126(b), the plan contains:

  • The written hazard analysis (117.130).
  • Preventive controls: process, food allergen, sanitation, supply-chain and others (117.135).
  • The supply-chain program, where a supplier controls a hazard.
  • The recall plan.
  • Monitoring procedures (117.145).
  • Corrective action procedures (117.150).
  • Verification procedures, such as calibration and record review (117.155 and 117.165).

How often, and what records to keep

  • Daily or per batch: monitoring of each preventive control, as your plan sets it.
  • Within 7 working days of the records being made: review of monitoring and corrective action records by or under a PCQI (117.165).
  • At least every 3 years: reanalysis of the whole plan, and sooner when a process changes or a control fails (117.170).
  • Keep required records at least 2 years after they were made (117.315). The food safety plan itself must stay on site; other records can be off site if you can produce them within 24 hours.

What an FDA investigator looks at

Investigators read the plan, then check that it is followed: monitoring records signed and dated, corrective actions written up when a limit was missed, thermometers and metal detectors verified, and records reviewed on time. They also walk the plant against the CGMPs in subpart B. Section 117.40 expects equipment to be designed and maintained so it can be cleaned and does not contaminate food, and 117.35 covers sanitary operations. A plant with broken equipment patched with tape, or with no record of when a cooler was last serviced, has a hard time showing control.

Run it in Dovient Lite

Dovient Lite handles the maintenance side of FSMA, not the plan itself. Add each piece of equipment as an asset, attach checklists for preventive maintenance, verification checks and sanitation clearance after repairs, and set schedules by date or run hours so a work order opens when each is due. Each completed checklist is kept on the asset's record with who did it and when, and completed work orders export as PDF for an FDA inspection or audit.

Start with Dovient Lite

Sources

Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.

Questions

Does every food plant need a food safety plan under FSMA?
Most FDA-registered facilities that manufacture, process, pack or hold human food do. Qualified facilities have modified requirements, and seafood and juice plants follow their own HACCP rules for the hazards those rules cover.
Who can write a food safety plan?
A preventive controls qualified individual (PCQI) must prepare it or oversee it. That person has completed FDA-recognized training or is qualified through job experience.
How long do I keep FSMA records?
At least 2 years after the date they were made (21 CFR 117.315). The food safety plan must be kept on site.
Is a food safety plan the same as a HACCP plan?
They are built the same way, but a food safety plan covers more than critical control points. It also includes sanitation, allergen and supply-chain controls, and a recall plan.