Dovient

Template · Compliance

ASC survey readiness checklist (CMS, AAAHC)

A survey readiness checklist for the building, equipment and records side of a CMS, state or AAAHC survey of an ambulatory surgery center, with the rules behind each item.

CMS Conditions for Coverage and AAAHC standards

A Medicare-certified ASC must meet the Conditions for Coverage in 42 CFR 416, Subpart C (416.40 to 416.54). The ones facility and equipment staff own most directly are the environment (416.44: Life Safety Code, NFPA 99, emergency equipment), infection control (416.51) and emergency preparedness (416.54). The state survey agency or an accrediting body with deeming authority surveys against them.

AAAHC standards cover the same ground (facilities and environment, infection prevention, emergency preparedness) and add their own expectations for policies, quality improvement and documentation. An ASC can choose an AAAHC accreditation survey or a Medicare deemed status survey, and AAAHC can select an accredited organization for a random survey between full surveys. Surveys can come with little notice, so the records must be current every month, not just before the visit.

What the surveyor checks on the building and equipment

  • Life safety records: generator tests, emergency lights, extinguishers, fire drills, sprinkler and fire alarm reports.
  • Medical equipment: every device on an inventory, with preventive maintenance done on the manufacturer's interval and current inspection stickers.
  • Emergency equipment in the operating rooms: immediately available, suited to your patients, maintained by appropriate personnel (416.44(d)).
  • Infection control: sterilizer monitoring records, clean and dirty areas kept apart, surfaces intact and cleanable.
  • Emergency preparedness: plan reviewed every 2 years, training every 2 years, and exercises at least once a year (416.54).
  • Environment: exits clear, fire doors closing and latching, nothing stored in corridors, ceiling tiles in place.

How often to run the checklist

Run it as an environment of care round once a month, and in full before an expected survey window. Each round, fix what you find and record who fixed it and when. A clean month-by-month record is the best evidence that the ASC is surveyed the same way it runs every day.

ASC survey readiness

Monthly, and before each survey window

Life safety

  • Generator weekly and monthly tests logged
  • Emergency lights tested this month
  • Extinguishers inspected and tagged this month
  • Fire drill held on each shift this quarter
  • Sprinkler and fire alarm reports current
  • Exits and corridors clear, fire doors latch

Medical equipment

  • Equipment inventory complete and current
  • Every device PM'd on schedule, sticker current
  • Electrical safety checks done where required
  • Out-of-service devices tagged and removed

Emergency equipment

  • Crash cart checked, seals and log current
  • Defibrillator tested, pads in date
  • Suction and oxygen ready in each OR
  • Malignant hyperthermia supplies in date

Infection control

  • Sterilizer biological and chemical tests logged
  • Clean and dirty areas separated
  • Surfaces, furniture and floors intact
  • Eyewash stations flushed and logged

Records and plans

  • Emergency plan reviewed within 2 years
  • Emergency exercise done this year
  • Contractor reports filed with each job
  • Open repair work orders followed up

Inspected by, date and notes go at the bottom of the printed sheet.

Run it in Dovient Lite

Add the generator, emergency lights, sterilizers, crash carts and each medical device as assets, and set this checklist as a monthly schedule. A work order opens each month, and the person doing the round marks each item pass, warning or fail on the phone with a photo; repairs found on the round become their own work orders. Before a survey, export the completed rounds, PMs and test work orders as a PDF.

Start with Dovient Lite

Sources

Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.

Questions

What are AAAHC standards?
The accreditation standards of the Accreditation Association for Ambulatory Health Care. They cover governance, quality, infection prevention, facilities and environment, emergency preparedness and clinical records, and an ASC accredited with deeming status is surveyed against the CMS Conditions for Coverage as well.
How often should an ASC check survey readiness?
Monthly, as an environment of care round, and in full before an expected survey. Surveys can come with little notice, so records must be current every month.
What records does a surveyor ask for on equipment and the building?
Life safety test logs, fire drill reports, medical equipment inventory and PM records, sterilizer monitoring, emergency equipment checks, and the emergency plan with training and exercise records.
Which CMS rules cover the ASC building?
42 CFR 416.44 requires the 2012 Life Safety Code and NFPA 99, and maintained emergency equipment. Emergency preparedness is in 416.54.