Dovient

ASC equipment maintenance software

Equipment PMs and life safety tests that hold up at survey

Biomedical equipment PMs, generator and fire safety tests and environment of care rounds come due on a schedule, and every completed check is ready as a PDF for CMS or accreditation surveyors.

Surgical team and equipment in an operating room

Generator, emergency lighting and fire safety tests

Set each test at its NFPA interval: the generator inspected weekly and run under load for 30 minutes monthly, emergency lights tested for 30 seconds monthly and 90 minutes yearly, fire extinguishers checked monthly, and fire drills quarterly on each shift. Each test opens as a work order with its checklist, and run times or load readings are typed in and marked pass or fail.

ASC life safety and NFPA 99 maintenance requirements
Dovient Lite preventive maintenance schedule: Generator, emergency lighting and fire safety tests for an ambulatory surgery center

Environment of care rounds on a phone

The nurse manager or facilities lead walks the center each month with a checklist: exits and corridors clear, fire doors closing and latching, extinguishers in place, medical gas zone valves labeled and reachable, eyewash flushed, and sterile storage temperature and humidity typed in and marked pass or fail. Anything wrong gets a photo, and a work order is opened for each fix.

Dovient Lite checklist on a work order (technician view): Environment of care rounds on a phone for an ambulatory surgery center

Staff report equipment problems from the OR

A monitor drops its SpO2 reading, or a stretcher's brake won't lock. The nurse picks the equipment in the app, describes the problem, adds a photo and marks it a breakdown if it can't be used. The people assigned to requests are notified, the facilities lead turns it into a work order, and the nurse can see when it's fixed.

Dovient Lite report a problem from the phone, with photo and breakdown flag: Staff report equipment problems from the OR for an ambulatory surgery center

Filters, gaskets and batteries in stock

Keep generator filters, sterilizer door gaskets, monitor batteries, HVAC filters and OR light lamps in the parts list with a minimum quantity. Parts used on a work order come off stock and add to that equipment's cost, and anything below its minimum is marked low stock on the list.

Dovient Lite parts inventory with stock levels and low-stock flags: Filters, gaskets and batteries in stock for an ambulatory surgery center

Biomedical equipment PMs by serial number

Anesthesia machines, patient monitors, defibrillators, electrosurgical units, sterilizers and suction units each have a record with model, serial number and the manufacturer's PM interval. When the biomed vendor finishes a PM or electrical safety test, their report is attached to the work order, and the record shows every service, repair and cost.

Medical and biomedical equipment maintenance program

Survey-ready records in one PDF

Before a CMS, state or accreditation survey (AAAHC or The Joint Commission), the administrator exports completed equipment PMs, generator tests and environment of care rounds as a PDF, with the date and who signed each one. Surveyors see the full record instead of a binder that may be missing a month.

ASC survey readiness checklist (CMS, AAAHC)

Repairs and vendor service in one list

Each repair or vendor visit is a work order with who is on it, photos, notes, status and the vendor's charge. Equipment out for repair is marked in maintenance or failed, so staff know not to use it. Overdue PMs show on the dashboard, so a missed one is caught before a surveyor finds it.

Which equipment fails most

The dashboard counts breakdowns and hours of downtime, shows the average time to repair (MTTR) and time between failures (MTBF), and lists the equipment that fails most often. When one sterilizer keeps going down, you have its history and cost in hand for the capital budget.

How setup works

  1. 1

    Add your equipment

    Import your equipment list from a spreadsheet (CSV or Excel) or add each machine with its model and serial number one at a time.

  2. 2

    Set PMs and tests

    Choose the checklists and intervals for each item: manufacturer PMs, generator and life safety tests, and monthly rounds.

  3. 3

    Invite your staff

    Nurses, techs and your facilities lead install the app and sign in. Each sees the checks and repairs assigned to them.

Set up Dovient Lite with us

Tell us how many operating rooms you have. We'll go through your equipment and life safety tests with you and set up your account.

Prefer to start on your own? Start with Dovient Lite

Surgery center checklists and guides

All templates

Questions

What is biomedical equipment maintenance software?

Software that keeps each medical device's PM schedule, service reports and repairs in one record. Dovient Lite does this for small teams in surgery centers, along with the building's life safety tests and environment of care rounds.

What maintenance is required for an ASC under the CMS Conditions for Coverage?

42 CFR 416.44 requires a safe, sanitary and functional environment, compliance with the 2012 editions of the Life Safety Code (NFPA 101) and the Health Care Facilities Code (NFPA 99), and emergency equipment that is maintained and ready. Surveyors check this against Appendix L of the CMS State Operations Manual.

How often must an ASC generator be tested?

NFPA 110, which NFPA 99 references, calls for a weekly inspection and a monthly run under load for at least 30 minutes, and for Level 1 systems a 4-hour run at least once every 36 months. Whether your center needs a generator depends on the equipment and anesthesia you use, so confirm with your life safety consultant.

How often are emergency lights tested?

Under NFPA 101, battery emergency lights get a 30-second functional test every month and a 90-minute test once a year, with written records of each.

How often do medical equipment PMs need to be done?

Most ASCs follow each manufacturer's recommended PM interval, and surveyors expect to see that it was done and documented. Dovient Lite holds each device's interval, opens the PM when it's due, and keeps the vendor's report on the device's record.

Does Dovient Lite replace our biomed vendor?

No. Your vendor still does the PMs and electrical safety tests. Dovient Lite schedules them, keeps their reports and charges on each device, and shows anything overdue.

If a round or test item fails, does Dovient Lite open a work order?

Not automatically. The person checking marks the item fail with a photo, and the facilities lead or nurse manager opens a work order for the fix.

Does it remind us before a PM or test is due?

Dovient Lite opens the work order on the due date and assigns it to the people set on that schedule. It doesn't send reminders ahead of time, so set vendor PMs a few weeks early if the vendor needs to book a visit. Anything not done on time shows as overdue on the dashboard.

Can we see repair and service costs per device?

Yes. Parts used on a work order come off stock and their cost is added to that device, along with labor and vendor charges you enter. Each record shows what it has cost this year.

Is Dovient Lite a healthcare CMMS?

Yes, for a surgery center. It is healthcare maintenance software that holds your medical equipment management program (each device, its PM interval and its service history), the building and life safety tests, and every repair with its cost.

How much does Dovient Lite cost?

Plans and prices are on the Dovient Lite pricing page: dovient.com/lite/pricing.

Reviewed

Equipment PMs and life safety tests that hold up at survey