What a reserve study is

A reserve study lists the major components the association must repair or replace (roofs, paving, elevators, boilers, pool equipment, exterior paint), estimates each one's remaining useful life and replacement cost, and sets a funding plan so the money is there when each is due. It has two parts: a physical analysis of the components and a financial analysis of the reserve fund.

It is done by a reserve specialist or engineer. The board uses it to set the reserve line in the annual budget, which is why it often sits next to the HOA budget template or condo budget template in the board's files.

HOA reserve requirements in some states

Reserve rules are set by each state, and many states have none. Two common examples:

  • California, Civil Code 5550: at least once every three years, the board has a visual inspection of the accessible areas of major components done, when their replacement value is at least half the gross budget. The board reviews the study every year. The study must list major components with under 30 years of remaining life, estimate their remaining life and cost, the annual contribution needed, and a funding plan.
  • Florida, Statute 718.112(2)(g): condo buildings three habitable stories or higher need a structural integrity reserve study at least every 10 years. It must cover the roof, structure, fireproofing and fire protection, plumbing, electrical, waterproofing and exterior paint, windows and exterior doors, and other items over $25,000 that affect those.
  • Other states such as Washington, Nevada and Oregon have their own rules. Check your state statute and your governing documents.

Build a component maintenance plan around the study

A reserve study assumes each component gets normal maintenance. If the roof drains are never cleared or the boiler is never serviced, the remaining life in the study is wrong. A component maintenance plan lists the upkeep for each reserve item so it reaches the life the study expects.

  1. Take the component list from the reserve study and give each item a record with its install date and location.
  2. For each one, write the routine maintenance: roof walk and drain cleaning twice a year, paving crack seal every few years, elevator service monthly, boiler service yearly, exterior sealant check yearly.
  3. Schedule each task and keep the completed record with photos and cost.
  4. Before each study update, give the reserve specialist the repair history and costs for each component. Repeated repairs are a sign the remaining life should be shortened.

Records to keep

  • The current reserve study and every prior one.
  • Maintenance and repair records for each reserve component, with dates and costs.
  • Contractor and engineer inspection reports.
  • Board minutes showing the annual review and funding decisions.

Run it in Dovient Lite

Add each reserve component as an asset with its location, then set date-based preventive maintenance schedules for its upkeep with a checklist attached. Each work order keeps the photos, comments, parts and cost, and all of it adds to that component's history. Before a study update, export the completed work orders as PDF for the reserve specialist and the board.

Start with Dovient Lite

Sources

Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.

Questions

How often does an HOA need a reserve study?
It depends on the state. California requires a visual inspection at least every three years with an annual review, and Florida requires a structural integrity reserve study at least every 10 years for condo buildings three stories or higher.
What is the difference between a reserve study and a maintenance plan?
The reserve study plans the money for replacing major components. The maintenance plan is the routine upkeep that makes those components last as long as the study assumes.
Who prepares a reserve study?
A reserve specialist or engineer hired by the board. The board gives them the component list and the repair history, and reviews the result each year.
What maintenance schedule should an HOA follow for reserve items?
Twice-yearly roof and drain checks, yearly boiler and fire system service, monthly elevator service, and periodic paving and sealant work, adjusted to your components and the study.