What has to be done and who requires it
There is no single federal rule for association maintenance. The duties come from your governing documents (the declaration says what the association must maintain), state condo and HOA statutes, the local fire code, the health department for pools, and your insurer.
Fire protection is the area most often written up. Sprinkler systems, fire alarms and fire pumps are inspected and tested by a licensed contractor on the schedules in NFPA 25 and NFPA 72, as adopted by your fire marshal. Portable extinguishers get a monthly visual check and yearly service. Exit signs and emergency lights are tested monthly and yearly under the life safety code your city enforces.
Pools open only to residents of a residential development are public pools under the federal Virginia Graeme Baker Pool and Spa Safety Act, so drain covers must meet the anti-entrapment standard, and the state or county health code sets water testing and gate rules.
Some states add building inspections. Florida, for example, requires condo buildings three habitable stories or higher to have a structural integrity reserve study at least every 10 years (Fla. Stat. 718.112(2)(g)).
How often: a common-area schedule
- Daily in season: pool chemistry, gate latch and posted rules.
- Weekly: walk of lobbies, halls, garage and trash rooms for lights out, spills and trip hazards.
- Monthly: the checklist below, plus extinguisher checks and generator run.
- Quarterly: HVAC filters in common areas, roof drains and gutters, sump and ejector pumps.
- Twice a year: roof walk, exterior sealant and paint check, irrigation start-up and shut-down.
- Yearly: sprinkler, fire alarm and backflow tests by contractors, elevator inspection, dryer vent cleaning where the association owns them.
Records the board should keep
Keep every contractor inspection report, the monthly checklists, the work orders for each repair with dates and cost, and vendor invoices. Owners can usually ask to see association records under state law, and the reserve study specialist and the insurer will ask for the repair history of the roof, elevators, boilers and paving. A dated photo of each failed item and its repair answers most disputes about what was done and when.
HOA and condo common area inspection
Monthly, for each building
Life safety
- Exit signs lit, emergency lights work on test
- Extinguishers in place, gauge in the green
- Fire doors close and latch on their own
- Stairwells clear, handrails secure
- Fire alarm panel shows normal, no trouble lights
Lobbies, halls and garage
- All lights working, no exposed wiring
- No trip hazards on floors or carpet
- Entry doors and closers working, locks secure
- Garage gate opens, closes and reverses
- No water on garage floor or stains on ceiling
Building systems
- Elevator phone connects, certificate posted
- Boiler or mechanical room clean, no leaks
- Sump and ejector pumps run, alarm works
- Generator ran its monthly test
Exterior and amenities
- Roof drains and gutters clear
- No trip hazards on walkways or parking lot
- Pool gate self-closes and latches
- Trash room clean, doors close, no pests
Inspected by, date and notes go at the bottom of the printed sheet.
Run it in Dovient Lite
Add each building, the pool and the major equipment (elevators, boilers, generator, gate) as assets with their locations, then set a monthly schedule with this checklist and yearly schedules for the contractor inspections. The manager marks each item pass, warning or fail on the phone with photos, and attaches the contractor's report to the work order. For anything that fails, the manager opens a work order, and every repair adds to that asset's cost history for the board.
Start with Dovient LiteSources
- Florida Statutes, Condominium association bylaws, Fla. Stat. 718.112(2)(g)
- NFPA 25, Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems
- CPSC, Pool and spa drain covers (Virginia Graeme Baker Pool and Spa Safety Act), 16 CFR part 1450
Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.
Questions
- What should an HOA maintenance checklist include?
- Life safety items (exit lights, extinguishers, fire doors), lobbies, halls and garage, building systems such as elevators, pumps and the generator, and exterior items like roof drains, walkways and the pool gate.
- How often should common areas be inspected?
- A walk each week and a full checklist each month works for most buildings, with seasonal roof and exterior checks and yearly contractor inspections for fire systems and elevators.
- What maintenance records should a condo association keep?
- Contractor inspection reports, monthly checklists, work orders with dates and costs, and invoices. Your state statute and governing documents set how long and who can see them.
- Who is responsible for repairs, the HOA or the owner?
- Your declaration decides. It lists which parts are common elements the association maintains and which are the owner's, such as windows or water heaters in many buildings.