Dovient

Template · Compliance

Dental OSHA & infection-control compliance checklist

A dental OSHA and infection control checklist for the office manager: the written programs, the recurring checks, and the records an inspector or state board will ask for.

Which rules apply to a dental office

  • Bloodborne pathogens, 29 CFR 1910.1030: exposure control plan, sharps handling, hepatitis B vaccine, training and records.
  • Hazard communication, 29 CFR 1910.1200: chemical inventory, labels, safety data sheets and training.
  • Eyewash where staff can be splashed with corrosive chemicals, 29 CFR 1910.151(c).
  • CDC infection control guidance for dental settings, which many state dental boards adopt or enforce.
  • EPA dental amalgam rule, 40 CFR Part 441, for offices that place or remove amalgam.

Dental OSHA requirements and how often

  • Exposure control plan: reviewed and updated at least once a year, and when tasks or procedures change (1910.1030(c)(1)(iv)). The review includes looking at safer sharps devices.
  • Bloodborne pathogens training: at hire and at least once a year, within one year of the last session ((g)(2)).
  • Hepatitis B vaccine: offered within 10 working days of starting a job with exposure ((f)(2)(i)).
  • Sharps containers: closable, puncture resistant, leakproof, labeled, upright, close to use, and replaced before they overfill ((d)(4)(iii)(A)).
  • Engineering controls: examined and maintained or replaced on a regular schedule ((d)(2)(ii)).
  • Sterilizers: CDC recommends a spore test (biological indicator) at least weekly for each sterilizer, with a control from the same lot.

Records to keep

An OSHA inspector usually asks for the written exposure control plan and when it was last reviewed, the training records, the hazard communication program and SDS binder, and walks the operatories and sterilization area. A dental board inspector will look at the sterilization area, the spore test log and the waterline maintenance. Use this dental osha compliance checklist monthly, and do the plan review once a year.

  • Training records for 3 years from the date of training (1910.1030(h)(2)(ii)).
  • Employee exposure medical records for the length of employment plus 30 years ((h)(1)(iv)).
  • Sharps injury log, if your office is required to keep an OSHA injury and illness log ((h)(5)).
  • Spore test results for each sterilizer. Many state dental boards set how long to keep them.
  • Amalgam separator inspections, repairs, replacements and pickups for 3 years (40 CFR 441).

Dental OSHA and infection control checklist

Monthly walk, plus the weekly and yearly items noted

Written programs (yearly)

  • Exposure control plan reviewed this year
  • Safer sharps devices evaluated and noted
  • Hazard communication program current
  • Bloodborne pathogens training done this year

Sterilization (weekly)

  • Spore test run on each sterilizer this week
  • Spore test result passed and filed
  • Cycle printouts or logs reviewed
  • Instruments packaged and dated

Sharps and waste

  • Sharps containers upright and near use
  • No sharps container past the fill line
  • Regulated waste bagged and labeled
  • Amalgam separator inspected and logged

Safety equipment

  • Eyewash flushed and water runs clear
  • PPE stocked in each operatory
  • SDS on file for every chemical in use
  • Secondary containers labeled

Inspected by, date and notes go at the bottom of the printed sheet.

Run it in Dovient Lite

Add each sterilizer, eyewash station and the amalgam separator as assets, and set weekly, monthly and yearly schedules with the matching checklist. The assistant marks each item pass, warning or fail on the phone and can attach a photo of the spore test report; each completed checklist stays on the asset's record with who did it and when. Export completed checks as PDF for an inspector or your yearly audit.

Start with Dovient Lite

Sources

Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.

Questions

How often does dental OSHA training have to be done?
Bloodborne pathogens training is required at hire and at least once a year after that. Hazard communication training is required at hire and when a new chemical hazard is introduced.
How often should a dental office do spore testing?
CDC recommends a biological indicator test at least weekly for each sterilizer. Many state dental boards make weekly testing a rule, so check your state's requirement and retention period.
How long do I keep dental OSHA records?
Bloodborne pathogens training records for 3 years, exposure medical records for the length of employment plus 30 years, and amalgam separator records for 3 years.
Does the exposure control plan need to be updated every year?
Yes. OSHA requires a review and update at least annually, and whenever tasks, procedures or positions change. Document the review and the safer devices you considered.