Dental office maintenance software

Spore tests, compressor and chair service in one log

The assistant records the weekly spore test on a phone, the compressor, vacuum and waterlines get serviced on schedule, and every repair and OSHA check stays on record.

Dental chair and delivery unit in a treatment room

Weekly spore tests and the sterilization log

Each autoclave gets a weekly spore test schedule, as CDC guidelines recommend and many state dental boards require. When the result is back from the mail-in lab or the in-office incubator, the assistant marks it pass or fail on the phone, types the test strip lot number and adds a photo of the report. Daily items, like checking the cycle printout and the chemical indicator, can be a checklist on the same sterilizer.

Spore testing and autoclave sterilization log
Dovient Lite checklist on a work order (technician view): Weekly spore tests and the sterilization log for a dental office

Compressor, vacuum, waterline and chair maintenance

Set each piece of equipment on its own schedule: drain the compressor daily and change its intake filter on the hours in the manual, clean the vacuum system's trap weekly, shock and test the dental unit waterlines on your treatment product's interval, and have the chairs and delivery units serviced once a year. The work order opens when it's due and goes to the assistant or office manager you set.

Dental equipment maintenance schedule
Dovient Lite preventive maintenance schedule: Compressor, vacuum, waterline and chair maintenance for a dental office

Staff report problems from the operatory

Suction is weak in Op 3, or a handpiece coupler is leaking. The hygienist picks the equipment in the app, describes the problem, adds a photo and marks it a breakdown if the room can't be used. The people assigned to requests (usually the office manager) are notified, turn it into a work order, and the hygienist can see when it's fixed.

Dovient Lite report a problem from the phone, with photo and breakdown flag: Staff report problems from the operatory for a dental office

Spore strips, filters and separator cartridges in stock

Keep spore test strips, waterline treatment cartridges or tablets, compressor intake filters, vacuum trap screens and amalgam separator cartridges in the list with a minimum quantity. Items used on a work order come off stock, and anything below its minimum is marked low stock on the list.

Dovient Lite parts inventory with stock levels and low-stock flags: Spore strips, filters and separator cartridges in stock for a dental office

OSHA and infection control records in one PDF

Weekly eyewash flushes, monthly extinguisher checks, the yearly review of your bloodborne pathogens exposure control plan and sharps container pickups each become a scheduled check. The completed records export as a PDF with dates and names, ready for an OSHA inspector, a state dental board visit or your own yearly audit.

Dental OSHA and infection control compliance checklist

Amalgam separator, X-ray and each unit's history

Each piece of equipment has its own record with its schedule, every work order, the parts used and what it has cost. The amalgam separator's inspections and cartridge changes are kept there, and the EPA dental amalgam rule (40 CFR 441) asks you to keep those records for three years. X-ray units carry the state radiation inspection report and the service company's visits.

Every repair in one list, with the dealer's service charges

Each repair is a work order: who reported it, who is on it, the photos, notes and status. When the dealer's technician fixes the compressor or a chair, the service charge goes on the work order and adds to that unit's cost. Overdue work shows on the dashboard.

How setup works

  1. 1

    Add your equipment

    Import your equipment list from a spreadsheet (CSV or Excel) or add autoclaves, compressors, chairs and X-ray units one at a time.

  2. 2

    Set checks and schedules

    Choose the checks each unit needs (weekly spore test, waterline testing, OSHA items) and how often they come due.

  3. 3

    Invite your team

    Assistants, hygienists and the office manager install the app and sign in. Each sees the checks and repairs assigned to them.

Set up Dovient Lite with us

Tell us how many operatories you have. We'll go through your equipment and required checks with you and set up your account.

Prefer to start on your own? Start with Dovient Lite

Dental office checklists and guides

All templates

Questions

What is dental office maintenance software?

Software that keeps a practice's equipment checks, scheduled service and repairs in one record. Dovient Lite does this for small teams: spore tests and OSHA checks on a phone, equipment service on a schedule, and a full history and cost for each unit.

Is Dovient Lite dental practice management software?

No. Scheduling, charting, billing and patient records stay in your practice management software. Dovient Lite covers the equipment and the safety and sterilization checks, and runs alongside it.

How often should a dental office run spore tests?

CDC's infection control guidelines for dental settings recommend a biological indicator (spore) test at least weekly for each sterilizer, and for every load that contains an implantable device. Many state dental boards make weekly testing a rule and set how long to keep the log, so check your state.

What does OSHA require of a dental office?

The bloodborne pathogens standard (29 CFR 1910.1030) requires a written exposure control plan reviewed at least once a year and yearly training for exposed staff. Hazard communication (29 CFR 1910.1200) covers chemical labels and safety data sheets, and an eyewash is required where staff handle corrosive chemicals (29 CFR 1910.151(c)).

What does the EPA amalgam separator rule require?

Offices that place or remove amalgam must use an amalgam separator, inspect and maintain it as the manufacturer says, and keep records of inspections, repairs, replacements and amalgam pickups for three years (40 CFR 441). Some specialties, such as orthodontics, are exempt.

How do I test dental unit waterlines?

CDC guidance is that dental unit water used for routine care should meet the EPA drinking water standard (500 CFU/mL or less of heterotrophic bacteria). Follow your waterline treatment product's maintenance and testing interval. In Dovient Lite the result is typed into the checklist and marked pass or fail.

If a spore test fails, does Dovient Lite take the autoclave out of service?

Not automatically. The assistant marks the test fail, sets the autoclave's status to failed so everyone sees it is out of use, and the office manager opens a work order for the follow-up.

Can I see what each piece of equipment costs to maintain?

Yes. Parts used on a work order come off stock and their cost is added to that unit, along with labor and the dealer's service charges you enter. Each record shows what it has cost this year.

What goes on a dental office cleaning and end of day checklist?

Typically: surfaces disinfected in each operatory or surgery, waterlines flushed, suction lines cleaned with the evacuation cleaner, the amalgam trap checked, the sterilization area cleaned and the autoclave log completed. In Dovient Lite that is a daily dental clinic checklist on a phone, and completed checklists export as a PDF when an inspector asks.

How much does Dovient Lite cost?

Plans and prices are on the Dovient Lite pricing page: dovient.com/lite/pricing.