Season opening and winterizing checklists
Set spring opening as a yearly schedule: de-winterize and flush water lines, turn on and test each pedestal, open the bathhouses, check the dump station. Set fall closing the same way: blow out lines, drain water heaters, shut off pedestals. The work orders open on their dates with the checklist attached, assigned to the crew you set.
Campground and RV park maintenance checklist
RV pedestal and site checks
Walk each loop with a checklist per site: 30 and 50 amp receptacles, breakers, GFCI on the 20 amp outlet, pedestal cover and post, water spigot, sewer cap, fire ring and picnic table. Mark each item pass, warning or fail on the phone and add a photo of a burnt receptacle or a missing sewer cap.

Camp hosts and staff report problems from the site
A camp host finds a tripped breaker at site 42 or a clogged shower drain in bathhouse B. They pick the site or building in the app, describe the problem, add a photo and mark it a breakdown if the site can't be rented. The maintenance lead is notified, turns it into a work order, and the office can see when it's fixed.

Pedestal parts and bathhouse supplies in stock
Keep 30 and 50 amp breakers, receptacles, sewer caps, shower valves, toilet flappers and water heater elements in the parts list with a minimum quantity. Parts used on a repair come off stock and add to that site's or building's cost, and anything below its minimum shows as low stock before the season opens.

Every repair in one list
Each repair is a work order with who reported it, who is on it, photos, notes and status. The manager assigns jobs from the office, the crew updates them from a phone out on the loops, and overdue work shows on the dashboard before a busy holiday weekend.
Water system and health department records
Parks with their own well schedule the sampling and checks their permit requires: chlorine residual typed in and marked pass or fail, the monthly or quarterly bacteriological sample, the annual backflow test. Completed checks export as a PDF for the sanitarian at the license inspection.
Campground and RV park regulationsPool chemistry and gate checks
If the park has a pool, the daily check covers chlorine and pH typed in and marked pass or fail, the gate latch, drain covers and the rescue equipment, with a photo when something is off. The season's checks export as a PDF for the health inspector.
Pool chemical log sheetEach mower, cart and well pump's history and cost
Service mowers and golf carts by hour meter and the well pump by date. Each record shows every work order, the parts used and what it has cost, and the dashboard lists the equipment that breaks down most, so you know what to replace over the winter.
How setup works
- 1
Add your sites and equipment
Import your sites, bathhouses and equipment from a spreadsheet (CSV or Excel) or add them one at a time.
- 2
Set checks and seasonal schedules
Choose the checklists you need (opening, closing, pedestals, water system) and when each one comes due.
- 3
Invite your crew and camp hosts
They install the app and sign in. Hosts report problems from the loops; the crew sees the work assigned to them.
Set up Dovient Lite with us
Tell us how many sites you run. We'll go through your seasonal checklists and water system checks with you and set up your account.
Prefer to start on your own? Start with Dovient Lite
Campground checklists and guides
All templatesPool checklists and logs
Questions
What is campground maintenance software?
Software that keeps the repairs, seasonal checklists and inspections for every site, building and machine in one place. Dovient Lite does this for campgrounds and RV parks: opening and winterizing checklists on a schedule, pedestal and bathhouse checks on a phone, and a repair history for each site and piece of equipment. It does not take reservations.
Does a campground need a state license?
Most states license campgrounds and RV parks through the health department or a state agency and inspect water, sewage, toilets and showers, and site layout. Florida, for example, regulates RV parks and recreational camps under Chapter 64E-15 of the Florida Administrative Code. Check your state's rules for the inspection frequency and records it expects.
Is a campground well a public water system?
Usually. Under the Safe Drinking Water Act, a system serving at least 25 people at least 60 days a year is a public water system, and a seasonal campground is typically a transient non-community system. That means routine bacteriological sampling and an annual nitrate test, on the schedule your state sets.
What electrical rules apply to RV pedestals?
RV site supply equipment is covered by NEC Article 551, adopted by your state or local code. It sets the 30 and 50 amp receptacles and the GFCI protection on the 125 volt outlets. Dovient Lite doesn't inspect for code, but a regular pedestal check catches the burnt receptacles and tripped breakers guests run into.
Can guests report problems with a QR code?
No. Problem reports come from signed-in staff and camp hosts. When a guest tells the office about a leak, the staff member files it from the phone with a photo and it goes to the maintenance lead.
Will it alert me if the chlorine reading is low?
No. Readings are typed into the checklist and marked pass or fail by the person doing the check. A failed item is saved with the check, and a person opens the work order to fix it.
Can I track repair costs per site or building?
Yes. Labor, parts and outside contractor charges on each work order add up on that site, bathhouse or machine. You can export cost by asset to see where the money went this season.
Do I need to rebuild the opening checklist every spring?
No. Opening and closing are yearly schedules, so the work order opens on the same date each year with the same checklist attached.
Is Dovient Lite campground management software?
No. It does not take reservations, payments or site assignments; keep your campground or RV park management software for those. Dovient Lite covers the maintenance side: sites and pedestals, the water system, bathhouses, mowers and repairs.
How much does Dovient Lite cost?
Plans and prices are on the Dovient Lite pricing page: dovient.com/lite/pricing.
Reviewed
Sites and bathhouses ready before the first camper pulls in




