Rules that shape campground maintenance
Campgrounds and RV parks are licensed by the state or county health department in most states, and the license rules cover sanitation, water, sewage, bathhouses and site spacing. Check your own state's rules with your inspector.
If your own well serves at least 25 people a day for at least 60 days a year, or has 15 or more service connections, it is a public water system under the Safe Drinking Water Act (40 CFR 141.2). Most campgrounds fall in the transient non-community class, which means routine sampling for coliform bacteria and nitrate on the schedule your state sets.
RV site electrical supply is covered by Part VI of Article 551 in the National Electrical Code (NFPA 70), as adopted by your state. Pedestal repairs and new circuits are work for a licensed electrician.
Seasonal schedule
- Season opening: dewinterize and flush water lines, test the well and disinfect if your state requires it, turn on and test every pedestal, open and inspect bathhouses, check the lift station or septic, start up the pool.
- Daily in season: bathhouse cleaning and supply check, trash, a look at the dump station.
- Weekly: walk every site with the checklist below, mow, check playground and fire rings.
- Monthly: check pedestal breakers and receptacles, GFCIs, water hydrants, lift station alarms, fire extinguishers.
- Season close: blow out and winterize water lines, shut down pedestals that will not be used, drain bathhouses, store and service mowers and carts.
What an RV site inspection covers
A site inspection is a walk of each pad from the road: the pad surface and drainage, the pedestal and its receptacles, the water hookup, the sewer connection cap, the fire ring and table, and overhead trees. Anything that could hurt a guest or damage an RV is fixed or the site is closed until it is.
Camp maintenance tracking: records to keep
- Water sample results and any notices from the state drinking water program.
- Site walk checklists and the repairs that followed.
- Electrical repairs by your electrician, with dates and sites.
- Opening and winterizing checklists for each season.
Campground and RV site inspection
Weekly in season, for each loop
Site and pad
- Pad level, no washouts or deep ruts
- Site number posted and readable
- No dead limbs over the pad
- Fire ring intact, table sound
Electrical pedestal
- Pedestal door closes, no damage
- Receptacles not burned or loose
- Breakers reset and hold
- GFCI receptacle trips and resets
Water and sewer
- Water hydrant not leaking, no puddles
- Sewer inlet cap in place
- No sewage odor or wet ground near inlet
Bathhouse and common areas
- Toilets, sinks and showers working
- Hot water at the tap
- Lights and exit signs working
- Dump station clean, rinse hose separate
Inspected by, date and notes go at the bottom of the printed sheet.
Run it in Dovient Lite
Add each loop or site, each bathhouse, the well and the lift station as assets with their locations, and set weekly, monthly and yearly schedules with the checklists attached; the opening and winterizing lists can run as yearly schedules. Staff mark each item pass, warning or fail on the phone with photos, and camp hosts with a login report problems as service requests. Every repair, part and cost stays on that site's or equipment's record.
Start with Dovient LiteSources
- EPA, National primary drinking water regulations: definitions, 40 CFR 141.2
- EPA, Information about public water systems
- NFPA 70, National Electrical Code, Article 551, Part VI
Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.
Questions
- What should a campground maintenance checklist include?
- Site pads, electrical pedestals, water hydrants and sewer inlets, bathhouses, the dump station, and common areas like the playground and pool, plus season opening and winterizing lists.
- How often should RV sites be inspected?
- Walk every site weekly in season and check pedestal breakers and GFCIs monthly. Check a site again after any guest reports a problem with power or water.
- Is a campground well a public water system?
- Yes, if it serves at least 25 people a day for at least 60 days a year or has 15 or more connections. Most campgrounds are transient non-community systems and sample on a schedule set by the state.
- What records does a campground need for inspections?
- Water sampling results, site and bathhouse inspection checklists, electrical repair records, and your state license paperwork. Your health department sets the details.