Dovient

Template

Brewery CIP cleaning SOP & log

A brewery SOP template for clean in place (CIP) of fermenters, brite tanks and lines, with a log sheet to record each cycle. Use your chemical supplier's concentrations and temperatures.

Why breweries keep a CIP log

Breweries registered with FDA are exempt from the preventive controls parts of the food safety rule for alcoholic beverages (21 CFR 117.5(i)), but the current good manufacturing practice rules in Subpart B still apply. They require food-contact surfaces to be cleaned as often as needed to protect against contamination (21 CFR 117.35). A CIP log is how you show tanks were cleaned and sanitized between batches.

Caustic and acid cleaners are also a worker safety issue. OSHA hazard communication (29 CFR 1910.1200) requires labeled containers, safety data sheets and training, and 1910.151(c) requires an eyewash or drench station where workers handle corrosives.

Brewery CIP cleaning procedure

  1. Lock out or isolate the tank: close product valves, remove or open the pressure relief as your tank maker says, and vent CO2 fully before anyone opens a manway. Never run hot caustic in a tank still under CO2; caustic absorbs CO2 and can pull a vacuum that collapses the tank.
  2. Pre-rinse with warm water until the drain runs clear, to remove yeast and trub.
  3. Caustic wash: circulate through the spray ball at the concentration and temperature on your cleaner's label, typically for 20 to 45 minutes. Watch the return to confirm the spray ball is covering the whole tank.
  4. Rinse with water until no caustic is left at the drain; check with pH paper.
  5. Acid wash: circulate the acid cleaner at the label concentration to remove beer stone and neutralize residue. Many breweries alternate acid every cycle or every few cycles.
  6. Rinse again if the acid product requires it.
  7. Sanitize with an EPA-registered no-rinse sanitizer at the label concentration shortly before filling. Follow the label, which is the legal directions for use.
  8. Inspect: look through the manway with a light for soil, check gaskets and the spray ball, and record the cycle on the log.

How often and what to record

Clean and sanitize fermenters and brite tanks after every batch, transfer hoses and heat exchanger after every use, and keg and packaging lines on their own schedule. Inspect and replace gaskets and spray balls on a set interval.

For each cycle, record the tank, date, each step with its chemical, concentration and temperature, the result of the visual check, and who did it. Keep the logs with the batch records so a quality problem can be traced to a cleaning cycle.

Brewery CIP cleaning log

Each CIP cycle, for each tank or line

Date and timeTank or lineCaustic (% and °F)Acid (% and minutes)Sanitizer (ppm)Rinse pH checkedVisual inspection OKInitials

The printed log has 10 rows per page.

Run it in Dovient Lite

Add each fermenter, brite tank and the heat exchanger as assets and attach a CIP checklist (CO2 vented, pre-rinse, caustic, rinse, acid, sanitize, visual check) to a work order for each cleaning. The brewer marks each step pass, warning or fail on the phone and notes concentrations and temperatures in the work order comments, and the completed check is saved on the tank's record with who did it and when. Gasket and spray ball replacement can run as a preventive schedule, with the parts coming off stock.

Start with Dovient Lite

Sources

Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.

Questions

How often should brewery tanks be cleaned?
Clean and sanitize fermenters and brite tanks after every batch, and hoses and the heat exchanger after every use. Run an acid cycle every time or every few cycles to control beer stone.
What records does a brewery need for cleaning?
A log of each CIP cycle with the tank, date, chemicals, concentrations, temperatures, inspection result and initials. FDA's good manufacturing practice rules in 21 CFR 117 Subpart B still apply to breweries.
Why vent CO2 before a caustic CIP?
Caustic reacts with CO2 and can create a vacuum strong enough to collapse a tank. Vent the tank fully and keep it open to air during a caustic cycle.
What concentration should I use for caustic and sanitizer?
Use the concentration and temperature on your cleaner's and sanitizer's labels. Sanitizer labels are legal directions for use.