Dovient

Brewery maintenance software

Glycol, brewhouse and canning line serviced between brews

The glycol chiller, brewhouse, keg washer and canning line get serviced on schedule, CIP and safety checks are done on a phone, and every repair and part stays on the equipment's record.

Brewer working beside stainless fermentation tanks

CIP cleaning logs on the brewer's phone

Each fermenter and brite tank gets a CIP checklist that follows your SOP: pre-rinse, caustic at the concentration and temperature you run (typed in, for example 2% at 160°F), rinse, acid, sanitizer, spray ball seen working, tank sealed. The brewer marks each step done and adds a photo if something looks off. The log is saved on that tank's record with who ran it and when.

Brewery CIP cleaning SOP and log
Dovient Lite checklist on a work order (technician view): CIP cleaning logs on the brewer's phone for a brewery

Glycol chiller and brewhouse maintenance on a schedule

Set the glycol chiller's checks by date: glycol level and concentration monthly, condenser coils cleaned quarterly, a refrigeration tech's service each spring before summer load. The brewhouse runs the same way: pump seals, mash rake gearbox oil, heat exchanger inspection, steam or boiler checks. Each work order opens when it is due, assigned to the person on the schedule, with its checklist attached.

Brewery equipment maintenance (glycol chiller, brewhouse)
Dovient Lite preventive maintenance schedule: Glycol chiller and brewhouse maintenance on a schedule for a brewery

Brewers report problems from the cellar

A fermenter jacket isn't holding temperature or the keg washer is leaking at a valve. The brewer picks the equipment in the app, describes the problem, adds a photo and marks it a breakdown if it stops production. Whoever handles maintenance is notified, turns it into a work order, and the brewer can see when it's fixed.

Dovient Lite report a problem from the phone, with photo and breakdown flag: Brewers report problems from the cellar for a brewery

Gaskets, seals and spare parts on the shelf

Keep tri-clamp gaskets, pump seals, keg washer valve seals, O-rings, filter cartridges and seamer parts in the parts list with a minimum quantity for each. Parts used on a work order come off stock and add to that equipment's cost, and anything below its minimum is marked low stock.

Dovient Lite parts inventory with stock levels and low-stock flags: Gaskets, seals and spare parts on the shelf for a brewery

Every repair in one list

Each repair is a work order: who reported it, who is on it, the photos, the notes and the status. The head brewer or production manager assigns jobs, the person doing the fix updates it from a phone, and overdue work shows on the dashboard. Outside calls, like the chiller contractor or the canning line tech, go on the work order with their charge.

Keg washer and canning line service by cycles

Give the keg washer a keg counter and the seamer a can or hour counter, and set service intervals on them: seamer chucks and rolls inspected every so many cans, keg washer valves and seals every so many kegs. Each machine's record shows its counter, its PM schedule, every repair, the parts used and what it has cost.

Packaging line downtime: what stops most

The dashboard counts breakdowns and hours of downtime, shows the average time to repair (MTTR) and time between failures (MTBF), and lists the equipment that fails most often. When the canning line keeps stopping at the seamer, you see it in the numbers before the next big release.

CO2 and safety checks on record

Set monthly checks for the CO2 monitor and alarm, pressure relief valves on tanks, eyewash stations and fire extinguishers, each with its checklist. Completed checks export as a PDF for the fire marshal or your insurer, with who did each one and when.

How setup works

  1. 1

    Add your equipment

    Import your tanks and equipment from a spreadsheet (CSV or Excel) or add them one at a time.

  2. 2

    Set checks and schedules

    Choose the checklists each piece needs (CIP, chiller service, CO2 monitor) and the intervals in days, kegs or cans.

  3. 3

    Invite your brewers and cellar staff

    They install the app and sign in. Each brewer sees the day's checks; whoever fixes things sees the repairs assigned to them.

Set up Dovient Lite with us

Tell us how many fermenters you run. We'll go through your equipment and cleaning checks with you and set up your account.

Prefer to start on your own? Start with Dovient Lite

Brewery checklists and guides

All templates

Questions

What is brewery maintenance software?

Software that keeps every tank's and machine's scheduled maintenance, cleaning logs and repairs in one record. Dovient Lite does this for small teams: CIP and safety checks on a phone, services by date or by keg and can counts, and a repair history and cost for each piece of equipment.

How often should a glycol chiller be serviced?

Common practice is to check glycol level and concentration monthly, clean the condenser coils every few months (more often in summer or a dusty space), and have a refrigeration technician service the chiller once a year before peak season. Your chiller's manual sets the exact intervals.

Does the FDA regulate brewery equipment?

Breweries register with the FDA as food facilities. Under 21 CFR 117.5(i), most are exempt from the hazard analysis and preventive controls rules, but they must still follow the current good manufacturing practices in 21 CFR 117 subpart B, which include keeping equipment cleanable and maintained.

Do I need a CO2 monitor in my brewery?

Many fire codes based on the International Fire Code (section 5307) require a gas detection system where more than 100 pounds of CO2 is stored indoors or below grade. Your state or city may have changed the rule, so check with your fire marshal. Dovient Lite records the regular check of the monitor; it doesn't connect to it.

Can I log CIP chemical concentrations and temperatures?

Yes, as typed text on each step of the CIP checklist, marked pass or fail. Dovient Lite doesn't check the numbers against a range or send an alert, so the brewer marks a step failed when it's off.

Does Dovient Lite manage recipes, batches or TTB reports?

No. Dovient Lite covers equipment maintenance, cleaning and safety checks, and repairs. Use your brewery management software for recipes, batches, inventory of ingredients and TTB reporting.

Can I track repair costs per piece of equipment?

Yes. Labor, parts and outside service charges on each work order add to that equipment's cost, and each record shows its full history, so you know what the old keg washer has cost before you replace it.

Does it remind me when the chiller service is due?

Dovient Lite opens the work order itself when a service comes due by date or by count, and assigns it to the people set on that schedule. Anything not done on time shows as overdue on the dashboard.

How much does Dovient Lite cost?

Plans and prices are on the Dovient Lite pricing page: dovient.com/lite/pricing.

Reviewed

Glycol, brewhouse and canning line serviced between brews