Dovient

Template

Auto shop safety & OSHA checklist

A monthly safety walk for an auto repair shop, covering car hoist requirements, compressed air, chemicals, fire safety and exits, with the OSHA rules behind each item.

OSHA rules that apply to auto repair shops

  • Vehicle lifts: no OSHA lift standard, but OSHA can cite unsafe lifts under the General Duty Clause. Follow ANSI/ALI ALOIM: a check before use each day and an inspection by a qualified lift inspector at least once a year.
  • Eyewash: where workers handle corrosives such as battery acid, quick-drench or eye flushing must be in the work area (29 CFR 1910.151(c)).
  • Fire extinguishers: visual check monthly, maintenance yearly (1910.157(e)).
  • Hazard communication: labels on every chemical container, safety data sheets on hand, and trained workers (1910.1200).
  • Compressed air for cleaning: below 30 psi, with chip guarding and eye protection (1910.242(b)).
  • Bench grinders: work rest within 1/8 inch of the wheel and the tongue guard within 1/4 inch (1910.215).
  • Exits: exit routes kept clear, and exit doors open from the inside without a key (1910.36 and 1910.37).

Auto repair shop license and state rules

Some states require auto repair shops to register or hold a license: for example, California's Bureau of Automotive Repair, Florida's Department of Agriculture and Consumer Services and the New York DMV each register repair shops. Other states have no statewide shop license but regulate specific work, such as state vehicle inspections or emissions testing. Many states also run their own OSHA-approved plans, which can add rules. Check with your state agency for licensing, and with your state plan if you have one.

How to run the safety walk

  1. Once a month, the owner or lead tech walks the whole shop with this checklist.
  2. Mark each item, and photograph anything that needs fixing.
  3. Fix small items on the spot; open a repair for anything else and assign it.
  4. Keep each completed walk. It shows an OSHA inspector or insurer that you check and fix hazards on a schedule.

Auto shop monthly safety walk

Monthly

Lifts and jacks

  • Daily lift checks done all month
  • Annual lift inspection label current
  • Jacks and jack stands rated and undamaged
  • Lift controls and locks work

Fire safety and exits

  • Extinguishers charged, tagged and unblocked
  • Exit routes clear, exit signs lit
  • Exit doors open from inside without a key
  • Oily rags in a closed metal can
  • Flammables in a cabinet or approved cans

Chemicals and first aid

  • Eyewash flushed and water runs clear
  • Every container labeled
  • Safety data sheets current and on hand
  • Spill kit stocked
  • First aid kit stocked

Air, tools and electrical

  • Blow guns limited to under 30 psi
  • Grinder work rest and tongue guard set
  • Air hoses and fittings not cracked
  • Cords and plugs not damaged
  • Electrical panels clear and closed

Housekeeping

  • Floors clean and dry, no oil spots
  • Battery charging area ventilated, no damage
  • Parts washer lid closes, fluid not overdue

Inspected by, date and notes go at the bottom of the printed sheet.

Run it in Dovient Lite

Add the shop, each lift, the compressor and the eyewash as assets, and set this checklist as a monthly schedule, with daily lift checklists on each lift. A work order opens when each is due; the owner or tech marks each item pass, warning or fail on the phone and adds a photo, and the walk is saved with who did it and when. Completed walks export as a PDF for an OSHA inspector or your insurer.

Start with Dovient Lite

Sources

Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.

Questions

What are the car hoist requirements for an auto shop?
OSHA has no lift-specific rule, but expects lifts to be safe. The ANSI/ALI ALOIM standard calls for a check before use each day, a yearly inspection by a qualified lift inspector, trained operators and the manufacturer's instructions at the lift.
Does an auto repair shop need an eyewash station?
Yes, if workers handle corrosives such as battery acid. OSHA requires quick-drench or eye flushing facilities in the work area for immediate use.
How often should a shop do a safety inspection?
A full walk monthly works for most shops, with daily lift checks and the monthly extinguisher check folded in. Keep each completed walk.
Do I need a license to run an auto repair shop?
It depends on the state. California, Florida and New York, for example, register repair shops, while some states have no statewide shop license. Check with your state agency.