What OSHA requires
OSHA's rule for compressed air receivers, 29 CFR 1910.169, requires a drain valve at the lowest point of every tank, opened often enough to keep oil and water from building up. Each tank needs a pressure gauge you can read and a spring-loaded safety valve, with no valve between the tank and the safety valve, and the safety valves must be tested frequently and at regular intervals.
Separately, 29 CFR 1910.242(b) says compressed air used for cleaning must be reduced to less than 30 psi, with chip guarding and personal protective equipment. Many states also register and inspect air receivers as pressure vessels, so ask your state boiler and pressure vessel office whether your tank needs a certificate.
Air compressor maintenance schedule
Rotary screw compressors are usually serviced by run hours, with oil, oil filter, separator and air filter on set intervals. Use your compressor's manual for the exact numbers.
- Daily: drain the tank (or check that the automatic drain is working), check the oil level on oil-lubricated units, listen for air leaks and unusual noise.
- Weekly: pull the safety valve ring to check it releases and reseats, clean the intake area, check the gauge reads normal.
- Monthly: inspect and clean the intake filter, check belt tension and wear, check the cooling fins are clean, look over hoses and fittings.
- Every 3 to 6 months, or by hours: change the oil and replace the intake filter, on the interval in the manual.
- Yearly: inspect the tank for corrosion and damage, check pressure switch and motor, service or replace the safety valve as the manufacturer says, and drain and service the air dryer and line filters.
Signs the compressor needs attention
- Runs longer or cycles more often than it used to: look for leaks in lines and tools.
- Water in the air lines or at the tools: the tank is not being drained or the dryer is not working.
- Oil in the air: worn rings or an overfilled crankcase.
- Rust weeping from the tank, a bulge or a leaking seam: take it out of service and have it inspected.
What to record
For each compressor, record the date, the hour meter if it has one, the checks done, the safety valve test, oil and filter changes, and any repairs with parts and cost. A dated safety valve test record is what an inspector or insurer will ask for.
Run it in Dovient Lite
Add the compressor, tank and dryer as assets with their location. Set a weekly schedule with a checklist for the drain, safety valve and leak checks, and a schedule by hour meter for oil and filter service, so a work order opens when each is due. Techs mark each item pass, warning or fail on the phone, filters and oil used come off stock, and the compressor's record shows every check and repair with the cost.
Start with Dovient LiteSources
- OSHA, Air receivers, 29 CFR 1910.169
- OSHA, Hand and portable powered tools and equipment, general, 29 CFR 1910.242(b)
Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.
Questions
- How often should I drain my air compressor tank?
- Daily in most shops, or at the end of each day of use. OSHA requires the drain to be opened often enough to keep liquid from building up in the tank.
- How often should the safety valve be tested?
- OSHA says frequently and at regular intervals. A weekly pull of the ring is a common shop practice; follow the manufacturer for replacement.
- How often should compressor oil be changed?
- It depends on the unit. Many piston compressors call for oil every 3 to 6 months or a set number of hours; check your manual.
- What else needs a regular check in an auto repair shop?
- Vehicle lifts, eyewash stations, fire extinguishers and tire machines all need regular checks. Each can run on its own schedule.