What the rules require
The US standard for using and maintaining vehicle lifts is ANSI/ALI ALOIM, published by the Automotive Lift Institute. It calls for the operator to check the lift before use, and for a qualified lift inspector to inspect each lift at least once a year, no matter what interval the manufacturer gives. Some manufacturers ask for more frequent inspections, and those apply too. ALI certifies lift inspectors through its Certified Lift Inspector program.
OSHA has no standard written only for car lifts. It can cite an unsafe lift under the General Duty Clause, and OSHA inspectors and insurers look to ALOIM and the manufacturer's manual. A dated record of daily checks, the annual inspection report and the repairs that followed is what shows you met them. New lifts should carry the ALI certification label, which means the design was tested to ANSI/ALI ALCTV.
Daily check and annual inspection
- Before use each day: the operator walks the lift with the checklist below. Any lift that fails a safety item is locked out until repaired.
- Monthly or per the manual: lubrication, cable and chain adjustment, and hydraulic fluid level.
- At least yearly: inspection by a qualified lift inspector, who covers structure, anchors, safety locks, cables or chains, hydraulics, controls, labels and the operator's manual. Lifts that pass are labeled.
- After a repair to a load-bearing part, or after the lift is moved: follow the manufacturer's instructions and have it checked before it goes back in service.
Records to keep
For each lift: the make, model, serial number and capacity, the daily checks, the annual inspection report and any repairs with the parts used. Keep the operating manual and the ALI safety materials at the lift. Train every tech who uses it, and keep a record of that training.
Car lift daily inspection
Before use each day, for each lift
Arms, pads and adapters
- Arm restraints engage and hold
- Lift pads present, not torn or worn through
- Height adapters and extensions on hand, undamaged
Locks, cables and chains
- Safety locks engage on each column at each stop
- Lock release works on both sides
- Cables or chains not frayed, kinked or stretched
- Sheaves and pulleys turn freely, not worn
- Equalizer cables adjusted evenly
Hydraulics and power
- No hydraulic leaks at cylinders, hoses or pump
- Lift rises and lowers smoothly, no jerking
- Controls return to off when released
- Power cord and switch not damaged
Structure and area
- Anchor bolts tight, no cracks in the concrete
- Columns plumb, no bent or cracked welds
- Capacity label and warning labels readable
- Area under and around the lift clear
Annual inspection
- Annual inspection done by a qualified inspector
- Inspection label on the lift is current
- Repairs from the last inspection completed
Inspected by, date and notes go at the bottom of the printed sheet.
Run it in Dovient Lite
Add each lift as an asset with its location and serial number, print its QR label, and set a daily schedule with this checklist and a yearly schedule for the annual inspection. The tech scans the label, marks each item pass, warning or fail on the phone and adds a photo of anything wrong; if the lift is unsafe, set its status to Failed so everyone sees it is down. Attach the inspector's report to the annual work order, and export the history as a PDF for an insurer or OSHA inspector.
Start with Dovient LiteSources
- ANSI/ALI ALOIM, Automotive Lifts: Safety Requirements for Operation, Inspection and Maintenance
- Automotive Lift Institute, Lift Inspection FAQ
- OSHA, General Duty Clause, OSH Act Section 5(a)(1)
Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.
Questions
- How often does a car lift need to be inspected?
- ANSI/ALI ALOIM calls for the operator to check it before use each day and for a qualified lift inspector to inspect it at least once a year. Follow the manufacturer's manual if it asks for more.
- Who can do the annual lift inspection?
- A qualified lift inspector. The Automotive Lift Institute certifies inspectors, and many insurers ask for an ALI Certified Lift Inspector.
- Does OSHA require car lift inspections?
- OSHA has no lift-specific standard, but it can cite unsafe lifts under the General Duty Clause and looks to ALOIM and the manufacturer's instructions. Records of daily checks and annual inspections show you followed them.
- What records should an auto repair shop keep for its lifts?
- Daily check records, the annual inspection report, repairs and parts for each lift, and training records for the techs who use them.