TL;DR
Brake fade with a spongy pedal means fluid contamination or worn pads. Check brake fluid for water contamination first (boiling point drops sharply with water content), then measure pad thickness.
What you might see
- longer stopping distance than before
- pedal goes to the floor before braking
- burning smell from wheel end after heavy use
- brake pedal feels spongy
Likely causes
Brake pads or shoes worn below minimum thickness, reducing stopping torque
Brake fluid contaminated with water, reducing the boiling point and causing vapor lock under sustained braking
Brake drum or rotor scored beyond the service limit
Brake adjuster seized, allowing excessive pad-to-drum clearance
Required tools
- Vernier calipers or brake pad thickness gauge
- Drum micrometer
- Brake fluid moisture test strip
- Brake bleeding kit
- LOTO kit
- Wheel chocks
Safety first
- Do not operate a forklift with brake fade. It is an immediate out-of-service condition.
- Brake dust may contain hazardous materials. Use a dedicated brake cleaner spray; do not blow out drums with compressed air.
Procedure
- 1
Lock out the forklift and chock all wheels.
- 2
Remove the wheel and drum. Measure pad or shoe thickness. The Toyota 8FGU minimum thickness is typically 2 mm bonded lining. Replace at or below minimum.[1]
- 3
Measure drum inside diameter. If the drum is more than 1 mm above the nominal diameter or shows deep scoring, it must be resurfaced or replaced.[1]
- 4
Test the brake fluid with a moisture test strip or a refractometer if available. Fluid with more than 3% water content must be flushed and replaced with fresh DOT-specified fluid.
- 5
Check the brake adjusters. Manual adjustment stars should rotate freely. Apply penetrating oil to seized adjusters; replace if they cannot be freed.
- 6
Reassemble the brakes and adjust the drum-to-shoe clearance to the Toyota specification before bleeding.
- 7
Bleed all four corners of the brake system to remove air. Start at the wheel furthest from the master cylinder.
Sources
Toyota 8-Series Forklift Operator and Maintenance Manual, Toyota Material Handling
Toyota 8FGU Series Forklift Service Manual, brake inspection and adjustment procedures (general)
View source
More guides for Toyota Material Handling 8FGU
How to fix rapid battery discharge on a Toyota 8FGU forklift
Rapid discharge is usually a dead cell or a charger that is not completing full charge cycles. Measure individual cell voltages fully charged to identify a dead or reversed cell.
How to fix slow hydraulic lift on a Toyota 8FGU forklift
Slow lift under load is usually a worn gear pump or a relief valve set below spec. Check hydraulic oil level first, then measure lift pressure against the Toyota specification.
How to fix a mast cylinder seal leak on a Toyota 8FGU forklift
A weeping cylinder rod seal must be replaced. Inspect the rod for scoring before fitting a new seal. A scored rod will cut the new seal immediately.
How to fix hard or loose steering on a Toyota 8FGU forklift
Hard steering points to the power steering pump or orbitrol valve. Loose steering with clunking is tie-rod or king pin wear. Check steering fluid level before anything else.
Related learning guides
Equipment Breakdown Response
The step-by-step playbook for the first 15 minutes after a critical machine goes down.
Read guideHydraulic System Troubleshooting
Diagnose the most common hydraulic failures, fast.
Read guideElectrical Fault Finding
Step-by-step electrical fault diagnosis for plant technicians.
Read guideStop fixing the same fault twice.
Dovient turns guides like this into your team's shared playbook, with AI that catches recurring issues before they break the line.