TL;DR
Remove the rope from service if 6 or more broken wires appear in any rope lay length, or if the rope diameter is reduced by more than 10% from nominal. Do not attempt to repair a damaged wire rope.
What you might see
- visible broken wires protruding from the rope
- kinks or birdcaging in the rope length
- rope diameter visibly reduced at a point
- corrosion or rust on rope strands
Likely causes
Fatigue from cyclic bending over the sheaves, especially at the dead-end termination
Corrosion from moisture, chemicals, or inadequate lubrication attacking individual strands
Abrasion from contact with the sheave grooves when rope is misgrooved or sheave is worn
Kinking from a previous improper unreeling or from a load swing event
Required tools
- Wire rope calipers
- Clean rag
- Konecranes-specified wire rope lubricant
- LOTO kit
- Replacement rope per CXT nameplate specification
Safety first
- Wear heavy leather gloves when handling wire rope. Broken wire ends cause serious lacerations.
- Lock out the crane before performing any rope inspection or replacement.
- Never repair a damaged wire rope. Replace it as a unit.
- Do not return the hoist to service after a rope replacement without a witnessed proof test.
Procedure
- 1
Lock out the crane at the main disconnect. Lower the hook block to the floor before starting rope inspection.
- 2
Clean the rope with a rag to remove surface grease. Walk the full rope length while rotating it to inspect all sides.[1]
- 3
Count broken wires in any rope lay length (approximately 6-8 times the rope diameter). Six or more broken wires in one lay is the discard threshold per applicable standards.[1]
- 4
Check rope diameter at multiple points with calipers. A 10% reduction from nominal indicates severe internal wear.
- 5
Inspect the rope end terminations and swaged fittings for corrosion, cracking, or evidence of slip.
- 6
If the rope passes inspection, apply Konecranes-specified rope lubricant over the full length from a dropper or brush, do not spray onto other components.
- 7
If rope replacement is required, use only the exact rope specification from the CXT hoist nameplate. Install and perform a proof test before returning to service.
Sources
Konecranes CXT Wire Rope Hoist & Crane Maintenance Manual, Konecranes
Konecranes CXT Wire Rope Hoist Maintenance Manual, wire rope inspection discard criteria and lubrication procedures (general)
View source
More guides for Konecranes CXT
How to diagnose a Konecranes CXT hoist that won't lift
If the motor runs but the hook does not move, the hoist brake is stuck engaged. If the motor does not run, read the fault code on the crane controller before anything else.
How to fix excessive hook block swing on a Konecranes CXT hoist
Persistent hook swing after stop is usually worn sheave bearings or a trolley alignment issue. Check sheave bearing play first. If bearings are good, adjust the anti-sway brake ramp in the drive.
How to fix hook drift after stop on a Konecranes CXT hoist
Drift after stop means the hoist brake is not holding. Check the brake air gap and pad thickness. A worn spring or glazed disc cannot hold a load safely.
How to diagnose and fix a limit switch failure on a Konecranes CXT hoist
A limit switch that does not stop the hoist is a safety-critical failure. Lock out the crane immediately. Test the switch contacts with a multimeter and replace if contacts do not close at the correct actuator position.
Related learning guides
Stop fixing the same fault twice.
Dovient turns guides like this into your team's shared playbook, with AI that catches recurring issues before they break the line.