TL;DR
Excessive overspray buildup in the dry scrubber reduces air flow and degrades paint quality. Follow the limestone powder charge schedule and replace the filter trays before build-up reduces booth airflow below specification.
What you might see
- booth airflow below the specification on the manometer
- paint film quality degrading with orange peel or contamination
- filter tray pressure drop increasing above the replacement threshold
- limestone powder usage rate below normal indicating blockage
Likely causes
Limestone powder charge rate set below specification for the paint throughput
Filter tray exchange interval exceeded allowing trays to saturate
High-humidity conditions reducing limestone powder effectiveness
Paint chemistry change increasing overspray adhesiveness to the dry scrubber media
Required tools
- Replacement filter trays (Durr-specified)
- Booth manometer or airflow meter
- PPE for paint waste handling (gloves, respirator with organic vapor cartridge)
- LOTO kit
Safety first
- Lock out booth fans before accessing filter trays. Booth fan blades are close to the tray module access area.
- Spent filter trays contain paint overspray waste that may be classified as hazardous. Wear gloves and respiratory protection and dispose per local hazardous waste regulations.
- Paint spray environments may contain flammable solvents. Verify the booth is purged and solvent concentrations are below LEL before any hot work.
Procedure
- 1
Check the current booth airflow measurement on the EcoDryScrubber control panel or booth manometer. Compare to the design airflow specification.[1]
- 2
Inspect the filter tray differential pressure indicator. Trays showing a pressure drop above the replacement threshold require exchange.[1]
- 3
Verify the limestone powder dose rate is set per the Durr specification for the current paint type and throughput.
- 4
Lock out the booth and recirculation fan before accessing the filter tray module.
Warning: Lock out booth ventilation fans before reaching into the filter tray module. Fan blades are exposed in some access configurations. - 5
Remove and replace the saturated filter trays following the Durr tray exchange procedure. Dispose of spent trays per the paint waste disposal regulation.
- 6
After tray replacement, restore power, check airflow, and confirm it returns to the specification before resuming paint operations.
Sources
Dürr Dürr EcoDryScrubber / EcoBell3 Paint Spray Booth general technical documentation, Dürr
Durr EcoDryScrubber paint booth operator and maintenance documentation, dry scrubber media management (general)
More guides for Dürr Dürr EcoDryScrubber / EcoBell3
How to inspect and maintain the EcoBell3 rotary atomizer on a Durr paint system
Bell cup wear or bearing failure on the EcoBell3 rotary atomizer causes paint film defects and uneven spray pattern. Measure bell cup runout and check bearing air pressure before each production run.
How to fix conveyor speed faults in a Durr EcoDryScrubber / EcoBell3 paint booth