Who inspects assisted living
Assisted living is licensed by each state, not by CMS. The state licensing agency runs a survey at licensure and then on a cycle it sets, plus visits after complaints. The state or local fire marshal inspects life safety, usually against the state's adopted edition of NFPA 101, the Life Safety Code, and the state's fire code.
Examples: Florida's Agency for Health Care Administration licenses assisted living facilities under Chapters 429 and 408 of the Florida Statutes. California's Department of Social Services, Community Care Licensing Division, licenses residential care facilities for the elderly. Texas Health and Human Services licenses assisted living under 26 TAC chapter 553, which also sets fire drill rules. Nursing homes and memory care units that are CMS-certified have extra federal requirements.
What surveyors look at on the building side
- Fire alarm, sprinkler and kitchen hood systems inspected and tagged by licensed contractors.
- Fire drills held and documented on the schedule your state sets.
- Exits, corridors and stairs clear, exit signs and emergency lights working.
- Fire doors and smoke doors closing and latching.
- Generator tested and logged, if you have one.
- Hot water at resident taps within your state's range.
- Call system working in rooms and bathrooms.
- Resident rooms, bathrooms and common areas clean and in good repair.
How often to walk it, and records to keep
Run the checklist below monthly, and again in the weeks before a survey window opens. Keep the vendor inspection reports, fire drill records, generator logs, water temperature checks, extinguisher checks and repair records together, in date order. Ask your licensing agency how long they must be kept; many states expect at least the last survey cycle on hand.
Assisted living life-safety readiness walk
Monthly, and before each survey window
Fire protection
- Fire alarm inspection report current
- Sprinkler inspection report current
- Extinguishers checked this month, tags current
- Kitchen hood system serviced, tag current
- Fire drills done and documented this quarter
Exits and doors
- Exits and corridors clear of storage
- Exit signs lit
- Emergency lights tested this month
- Fire and smoke doors close and latch
- Delayed-egress and locked doors work as approved
Building systems
- Generator weekly and monthly tests logged
- Hot water at resident taps within state range
- Call system works in rooms and bathrooms
- HVAC working, rooms at a comfortable temperature
Resident areas
- Grab bars secure in bathrooms
- Floors even, no trip hazards
- Furniture and beds in good repair
- Chemicals and sharps locked away
Inspected by, date and notes go at the bottom of the printed sheet.
Run it in Dovient Lite
Add the generator, fire panel, water heaters, call system and each wing or unit as assets. Attach this checklist to a monthly schedule, and set separate schedules for generator tests, extinguisher checks and water temperature checks, so a work order opens when each is due. Staff mark each item pass, warning or fail on the phone, and completed work orders export as PDF when the surveyor asks for records.
Start with Dovient LiteSources
- Florida AHCA, Assisted Living Unit
- California CDSS, Community Care Licensing Division
- Texas HHSC, Assisted Living Facilities, 26 TAC chapter 553
- NFPA 101, Life Safety Code
Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.
Questions
- How often are assisted living facilities inspected?
- Each state sets its own survey cycle, plus visits after complaints. The fire marshal inspects on the local fire code's schedule.
- What records should I have ready for a state survey?
- Fire alarm and sprinkler inspection reports, fire drill records, generator logs, extinguisher checks, water temperature checks and repair records, in date order.
- Does CMS inspect assisted living?
- No. Assisted living is licensed by the state. CMS surveys certified nursing homes, which have their own federal rules.
- How often should we do fire drills?
- Your state sets it. Texas, for example, requires drills on each shift each quarter. Check your state's rule and the fire marshal's requirements.