Who regulates assisted living
Assisted living is licensed by the states, not by the federal government. Each state has its own law and rules, its own name for the setting (assisted living, residential care, personal care home) and its own licensing agency, usually the health department, the human services agency or a health care administration.
Nursing homes are different. A nursing home that takes Medicare or Medicaid must meet the federal requirements in 42 CFR Part 483, and the state survey agency inspects it for CMS. The physical environment rules in 42 CFR 483.90 require the Life Safety Code (NFPA 101) and the Health Care Facilities Code (NFPA 99), along with requirements for emergency power, resident call systems and other building conditions. Memory care units inside assisted living are usually covered by extra state rules on secured doors, staff training and dementia care.
What most states require of the building
The details vary, but the same topics come up in nearly every state's rules and on every survey:
- Fire safety: fire drills on each shift on the state's schedule, fire alarm and sprinkler inspections by a licensed contractor, monthly extinguisher checks, exit signs and emergency lights tested.
- Emergency power and planning: generator tests where a generator is required, and a written emergency plan.
- Water: hot water held within the state's temperature range at resident taps, and a water management plan for Legionella.
- Physical plant: building, grounds and equipment kept in good repair, call systems working, resident rooms safe and clean.
- Records: dated, signed records of each drill, test and inspection, kept for the period the state sets.
Examples of state agencies
Read your own state's current rules for intervals and record periods, and ask your surveyor or the fire marshal where a requirement is unclear.
- Florida: the Agency for Health Care Administration licenses assisted living facilities under Chapter 429, Part I, Florida Statutes.
- Texas: Health and Human Services Commission, under 26 Texas Administrative Code Chapter 553.
- Ohio: the Department of Health licenses residential care facilities.
- Georgia: the Department of Community Health, Healthcare Facility Regulation.
- Illinois: the Department of Public Health licenses assisted living and shared housing establishments.
- Virginia: the Department of Social Services licenses assisted living facilities.
How to stay ready for the survey
- List every recurring check your state rules and your fire marshal require, with how often each is due.
- Give each one an owner and a written checklist.
- Record each check when it is done, with the date and who did it.
- Fix what fails and record the repair next to the failed check.
- Review the records each month so a missed drill or test is caught before the surveyor finds it.
Run it in Dovient Lite
Add the generator, fire alarm panel, sprinkler riser, water heaters and other systems as assets, and set each recurring check as a preventive schedule with its checklist attached. The work order opens when it is due, staff mark each item pass, warning or fail on the phone, and the completed check is saved on the asset with who did it and when. Before the survey, export the completed work orders as PDF.
Start with Dovient LiteSources
- CMS, Long-term care facilities: physical environment, 42 CFR 483.90
- Florida Statutes, Assisted Living Facilities, Chapter 429, Part I
- Texas HHSC, Licensing Standards for Assisted Living Facilities, 26 TAC Chapter 553
Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.
Questions
- Is assisted living regulated by the federal government?
- No. States license and inspect assisted living. Federal rules in 42 CFR Part 483 apply to nursing homes that take Medicare or Medicaid.
- What do assisted living surveyors look at in the building?
- Mostly life safety and upkeep: fire drill records, fire alarm and sprinkler inspections, extinguishers, emergency lighting, generator tests where required, hot water temperatures and general repair.
- Are memory care rules different?
- Usually yes. Most states add requirements for memory care units, such as secured exits, staff dementia training and extra staffing. Check your state's rules.
- How do I track assisted living compliance?
- Make a list of every recurring check with its interval, assign an owner, and keep a dated record of each one. A maintenance app does this by opening each check when it is due and saving the result.