Who sets the rules
Group homes are licensed by the state, usually by the developmental disabilities, human services or health agency. Each state writes its own physical site and fire safety rules, so your licensing rules are the checklist you are measured against. Examples are Florida's Agency for Persons with Disabilities (Chapter 65G-2, Florida Administrative Code) and Pennsylvania's Chapter 6400 rules for community homes (55 Pa. Code Chapter 6400).
Homes certified as Medicaid ICF/IID facilities also follow federal rules in 42 CFR 483.470. They require evacuation drills at least quarterly for each shift and under varied conditions, a written report and evaluation of each drill, and compliance with the Life Safety Code. Where clients who have not been trained to regulate water temperature can reach hot water, it must not exceed 110°F (483.470(d)(3)).
How often to check
- Daily: walk-through for hazards, doors and locks, and anything residents report.
- Monthly: the checklist below, including smoke alarm tests and fire extinguishers.
- On the interval your state sets: fire drills for each shift, and hot water temperature checks.
- Quarterly or twice a year: furnace filters, dryer vent cleaning, gutters.
- Yearly: furnace or boiler service, fire extinguisher service, and any inspections your state or fire marshal requires.
Records a licensing surveyor looks at
- Fire drill records with date, time, shift, how long evacuation took and any problems.
- Monthly home inspection checklists, signed and dated.
- Work orders showing each problem was repaired, with the date it was fixed.
- Smoke alarm tests, extinguisher tags and service records.
- Hot water temperature readings and furnace service reports.
How to do the monthly inspection
- Do it on a set day each month so it is never skipped when staff change.
- Walk every room, including residents' bedrooms with their permission, the basement and the yard.
- Test every smoke alarm with its test button and read the hot water temperature at a bathroom tap with a thermometer.
- Mark each item, photograph anything that fails, and report each problem for repair the same day.
- Sign and date the checklist, and file it with the repair records so a surveyor can match each problem to its fix.
Group home monthly safety inspection
Monthly, for each house
Fire safety
- Smoke alarms sound on test in every room
- CO alarms present and working
- Extinguishers in place, gauge in the green
- Exits and hallways clear
- Evacuation plan posted
Water and heat
- Hot water at or below the state limit
- Furnace filter clean, area clear of storage
- Water heater area clear, no leaks
- Dryer lint trap and vent clear
Rooms and bathrooms
- Bedroom windows open and screens intact
- Grab bars and railings secure
- No leaks, mold or slow drains
- No trip hazards on floors
- Medications and poisons locked
Kitchen and outside
- Appliances working and clean
- Refrigerator at 41°F or below
- Steps, ramps and walkways in good repair
- Outside lights working
Inspected by, date and notes go at the bottom of the printed sheet.
Run it in Dovient Lite
Add the house and its equipment (furnace, water heater, appliances, alarms) as assets, and set a monthly schedule with this checklist, plus schedules for fire drills and furnace service. The house manager marks each item pass, warning or fail on the phone with photos, and the check is saved with who did it and when. Staff report repairs as service requests, each repair is tracked as a work order to the day it was closed, and completed work orders export as PDF for the licensing visit.
Start with Dovient LiteSources
- CMS, Conditions of participation for ICF/IID: physical environment, 42 CFR 483.470
- Florida Administrative Code, Group home facility standards, Fla. Admin. Code R. 65G-2.012
- Pennsylvania Code, Community homes for individuals with an intellectual disability or autism, 55 Pa. Code Chapter 6400
Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.
Questions
- What should a group home inspection checklist include?
- Smoke and CO alarms, extinguishers, clear exits, hot water temperature, furnace and dryer vent, bedrooms and bathrooms, the kitchen, and outside steps and lighting. Match it to your state's licensing rules.
- How often do group homes need fire drills?
- Your state sets it. ICF/IID homes must drill at least quarterly for each shift under 42 CFR 483.470(i), and many state licensing rules require drills more often.
- What is the hot water limit in a group home?
- For ICF/IID homes, 110°F where clients not trained to regulate water temperature can reach it. State licensing rules set the limit for other homes.
- What records will the licensing surveyor ask for?
- Fire drill records, monthly home inspections, repair records with dates, smoke alarm and extinguisher checks, and service reports for the furnace and other systems.