How a reclaim system works and what goes wrong
Wash water drains to settling tanks or a grit pit where sand and sludge drop out and oil floats. A pump draws from the clear zone through cyclone separators or filters, odor is controlled with ozone, air or a biological treatment, and the reclaimed water goes back to the early wash arches. Fresh water is still used for the final rinse.
Most reclaim problems come from three things: sludge left too long in the tanks, clogged filters or cyclones, and odor when the water goes septic. All three are prevented by routine checks and on-time pump-outs.
Maintenance schedule
- Daily: check reclaim pump pressure, look and smell the reclaimed water, check chemical levels and that every dosing pump is drawing. Look for leaks at the chemical room.
- Weekly: clean strainers and filter screens, check the odor control system, verify dilution ratios against the chemical supplier's settings, check water softener salt and hardness.
- Monthly: measure sludge depth in each settling tank, clean or backflush cyclones, inspect dosing pump tubing and check valves, check the eyewash station.
- On your permit's interval or when sludge reaches the level set by your system maker or sewer permit: pump out the grit pit and settling tanks with a licensed hauler and keep the receipt.
- Yearly: have the reclaim maker or a service tech inspect pumps, controls and tanks, and review chemical safety data sheets with staff.
Rules that apply
- Sewer discharge: car wash water goes to the sanitary sewer, never a storm drain. Your city or sanitary district sets limits and pump-out requirements through its sewer use rules or a discharge permit, under the federal pretreatment program.
- California Water Code 10951: in-bay and conveyor car washes permitted and built after January 1, 2014 must recycle and reuse at least 60% of wash and rinse water, or use recycled water from a supplier for at least 60%. Self-service washes are excluded, and cities can require more.
- Chemicals: OSHA hazard communication (29 CFR 1910.1200) requires labeled containers, safety data sheets and staff training. Where workers handle corrosive chemicals, 1910.151(c) requires an eyewash or drench station close by.
- Other states and cities have their own water use and car wash rules. Ask your water district and sewer authority what applies to your site.
What to record
Keep a dated record of sludge depth readings, pump-outs with the hauler's receipt, filter and cyclone cleanings, chemical deliveries and dilution checks, and repairs. When a sewer inspector visits or an odor complaint comes in, those records show what was done and when.
Reclaim and chemical system weekly check
Weekly
Reclaim system
- Reclaim pump at normal pressure
- Strainers and filter screens cleaned
- Odor control running, water has no sour smell
- Tanks not near full sludge level
Chemical dosing
- Every dosing pump drawing chemical
- Dilution ratios match supplier settings
- Tubing and check valves not cracked or leaking
- Softener has salt, water hardness in range
Chemical room safety
- All containers labeled
- Safety data sheets available
- Eyewash flushes clean water
- No spills, drums on containment
Inspected by, date and notes go at the bottom of the printed sheet.
Run it in Dovient Lite
Add the reclaim system, each dosing pump and the softener as assets, and set daily, weekly and monthly schedules with the checklists attached. Attendants mark each item pass, warning or fail on the phone, note sludge depth or dilution readings in the work order comments, and attach the hauler's pump-out receipt as a photo. Parts like pump tubing and filters come off stock and add to the equipment's cost.
Start with Dovient LiteSources
- California Water Code, Car wash water recycling, Water Code 10951
- EPA, Pretreatment standards: general and specific prohibitions, 40 CFR 403.5
- OSHA, Hazard communication, 29 CFR 1910.1200
- OSHA, Medical services and first aid, 29 CFR 1910.151(c)
Rules change and vary by state and county. Check the current text with your inspector or authority having jurisdiction. Last reviewed 2026-11-15.
Questions
- How often should car wash reclaim tanks be pumped out?
- When sludge reaches the level your system maker or sewer permit sets, or on the interval in your permit. Measure sludge depth monthly so you know before it carries over into the pump.
- Do car washes have to recycle water in California?
- In-bay and conveyor washes permitted and built after January 1, 2014 must reuse at least 60% of wash and rinse water or use 60% recycled water, under Water Code 10951. Self-service washes are excluded.
- Why does my reclaim water smell?
- The water has gone septic, usually from too much sludge, low circulation or an odor control system that is not working. Pump the tanks, check the odor control, and keep water moving.
- What chemical records does a car wash need?
- Safety data sheets for every product, labeled containers and staff training records under OSHA hazard communication. A dilution check log helps control cost and wash quality.