Dovient

Car wash maintenance software

Catch worn brushes and failing pumps before the tunnel stops

Attendants do the opening check on a phone, conveyor and pump service comes due by car count or date, and every repair, part and hour of downtime stays on that equipment's record.

Car going through the brushes in an automatic car wash

Opening checks for the tunnel and bays

Before the first car, the attendant walks the tunnel: conveyor chain and rollers, wrap and mitter brushes, high-pressure nozzles, chemical lines and pumps, dryers, the entrance gate and the emergency stop. Each item is marked pass, warning or fail on the phone, with a photo of anything worn. Self-serve bays get their own check: wands, hoses, foam brushes and the pay station.

Car wash equipment maintenance checklist (daily, weekly, monthly)
Dovient Lite checklist on a work order (technician view): Opening checks for the tunnel and bays for a car wash

Conveyor, brush and pump service by car count

Add a car counter to the tunnel and set services by cars washed or by date: conveyor chain lubed and checked for stretch, high-pressure pump oil changed by pump hours, brush cloth replaced on the car count your equipment maker gives. Enter the count from the controller when you check it, and Dovient Lite opens the work order for anything due. A service can follow a date, a count, or whichever comes first.

Dovient Lite preventive maintenance schedule: Conveyor, brush and pump service by car count for a car wash

Attendants report problems from the lot

A dryer keeps tripping its breaker, a vacuum stops pulling, or the tire shine applicator misses. The attendant picks the equipment in the app, describes the problem, adds a photo and marks it a breakdown if it's out of use. The people assigned to requests are notified, the site manager turns it into a work order, and the attendant can see when it's fixed.

Dovient Lite report a problem from the phone, with photo and breakdown flag: Attendants report problems from the lot for a car wash

Nozzles, brush cloth and pump parts on the shelf

Keep nozzles, brush cloth, conveyor rollers, pump seal kits, belts and wand hoses in the parts list with a minimum quantity. Parts used on a repair come off stock and add to that equipment's cost, and anything below its minimum is marked low stock, so a cracked nozzle doesn't keep a bay closed for a week.

Dovient Lite parts inventory with stock levels and low-stock flags: Nozzles, brush cloth and pump parts on the shelf for a car wash

Reclaim system and chemical dosing upkeep

Make the reclaim system an asset with its own schedule: settling tanks checked for sludge depth, cyclone separators and filters cleaned, odor control checked, and the grit pit pumped out on the interval your sewer permit sets. Chemical dosing pumps and the water softener get weekly checks, and readings like dilution ratio or water hardness are typed into the checklist and marked pass or fail. Pump-out receipts and service reports are attached to the record.

Car wash water reclaim and chemical system upkeep

Every repair in one list, every bay's status

Each repair is a work order: who reported it, who is on it, the photos, notes, status and any charge from your equipment distributor's tech. The site manager assigns jobs from the office, attendants update them from a phone, and overdue work shows on the dashboard. Equipment that is down is marked failed, so everyone can see a bay or the tunnel is out.

What stops the tunnel most

The dashboard counts breakdowns and hours of downtime, shows the average time to repair (MTTR) and time between failures (MTBF), and lists the equipment that fails most. When the conveyor roller or a dryer motor keeps showing up, you can see what it has cost you and decide whether to rebuild or replace it.

Pump-out and safety records for inspectors

Export completed checks and work orders as a PDF when the city's sewer inspector, the fire marshal or your insurer asks: grit pit pump-outs, chemical storage checks, eyewash flushes and extinguisher inspections, each with a date and who did it.

How setup works

  1. 1

    Add your equipment

    Import your equipment list from a spreadsheet (CSV or Excel) or add the conveyor, brushes, pumps, dryers and bays one at a time.

  2. 2

    Set checks and service intervals

    Choose the checklists each site needs (opening check, weekly reclaim check) and the service intervals in car count, hours or days.

  3. 3

    Invite your attendants and managers

    They install the app and sign in. Attendants see the day's checks; whoever handles repairs sees the work assigned to them.

Set up Dovient Lite with us

Tell us how many wash locations you run. We'll go through your equipment and service intervals with you and set up your account.

Prefer to start on your own? Start with Dovient Lite

Car wash checklists and guides

All templates

Questions

What is car wash maintenance software?

Software that keeps a wash's daily checks, scheduled service and repairs in one record. Dovient Lite does this for small teams: opening checks on a phone, service by car count, hours or date, and a full history and cost for each piece of equipment.

Can I schedule maintenance by the number of cars washed?

Yes. Add a car counter to the tunnel or bay and set services every so many cars, every so many days, or whichever comes first. Dovient Lite doesn't read your tunnel controller or pay station, so a manager enters the count from it, and each new count opens a work order for anything due.

What wastewater requirements apply to a car wash?

It depends on your local sewer authority. Under the Clean Water Act, wash water shouldn't go to a storm drain, so most washes discharge to the sanitary sewer through a grit or oil interceptor under a local permit. The permit usually sets how often the pit is pumped out and which records to keep, and some cities and states also require reclaim. Check your permit for the exact rules.

What OSHA rules apply to car wash chemicals?

Hazard communication (29 CFR 1910.1200) requires labels, safety data sheets and training for the chemicals you use. Where workers handle corrosive presoaks or wheel cleaners, an eyewash or shower must be close by (29 CFR 1910.151(c)).

Does Dovient Lite alert me when a chemical reading is off?

No. Readings like dilution ratio, pH or water hardness are typed into the checklist and marked pass or fail by the person checking. Dovient Lite doesn't send alerts from them; a failed reading stays on the record for the manager to see.

If an opening check item fails, does Dovient Lite open a repair?

Not automatically. The attendant marks the item fail with a photo, and the site manager opens a work order for the repair.

Can I see repair costs per piece of equipment?

Yes. Parts used on a repair come off stock and their cost is added to that equipment, along with labor and distributor charges you enter. Each record shows what it has cost this year.

Does it remind me when service is due?

Dovient Lite opens the work order itself when a service comes due by date or by count, and assigns it to the people set on that schedule. Anything not done on time shows as overdue on the dashboard.

Do attendants need training to use it?

Not much. An attendant opens the app, picks the opening check and taps pass, warning or fail on each item. Photos come from the phone camera.

Is Dovient Lite car wash management software?

No. It does not run your point of sale, memberships or tunnel controller. It covers the equipment: scheduled service, opening checks, repairs, parts and what each machine costs to keep running.

How much does Dovient Lite cost?

Plans and prices are on the Dovient Lite pricing page: dovient.com/lite/pricing.

Reviewed

Catch worn brushes and failing pumps before the tunnel stops