TL;DR
Stop the motor immediately. A burning smell almost always means stator insulation breakdown. The motor needs to be rewound or replaced, do not attempt to restart it.
What you might see
- acrid burning odor
- visible smoke from the motor housing or conduit box
- ground fault indicator lit
- discolored windings visible through the conduit box
Likely causes
Stator winding insulation breakdown from sustained overheating
Moisture ingress causing winding-to-ground arcing
Severe phase imbalance burning one phase winding
Contaminated cooling air carrying flammable vapors
Required tools
- LOTO kit
- Megohmmeter (for the no-visible-damage case)
- Insulated screwdrivers
- Camera or phone for documentation
Safety first
- A burning motor is a fire hazard. If smoke is heavy or flames are visible, evacuate and call the fire response team.
- Do not open a hot conduit box. Wait for the motor to cool.
- Do not attempt to restart a motor with a burning smell, you risk a fire and irreversible insulation damage.
Procedure
- 1
STOP the motor immediately. Hit the local E-stop or open the upstream disconnect.
Warning: If smoke is significant or flames are visible, evacuate the area and call your fire response team. Do not approach a burning motor. - 2
Lock out and tag out the disconnect.
- 3
Wait at least 15 minutes for the windings and conduit box to cool before opening anything.
- 4
Open the conduit box and inspect for visible damage, discolored or charred windings, melted insulation, burned lead terminations.[1]
- 5
Photograph the damage for the maintenance record and the failure analysis.
- 6
If damage is visible, the motor cannot be repaired in the field. Tag it Out of Service.
- 7
If no visible damage, perform a megohmmeter test (see the won't-start procedure on this machine) to check insulation resistance.
- 8
Send the motor to a qualified motor rewind shop or order a replacement.
- 9
While waiting for repair, investigate the root cause, overload history, supply imbalance, ventilation problems, contamination. Do not return a replacement motor to service without addressing the root cause.
Sources
Baldor Reliance Industrial Motor Maintenance Manual, Baldor Electric Company (ABB)
Baldor Industrial Motor Maintenance Manual, winding inspection and insulation breakdown indicators (general)
View source
More guides for Baldor Super-E (EM/EJMM)
How to diagnose bearing noise and vibration on a Baldor Super-E motor
Vibration is most often a worn bearing. Listen for grinding, log a vibration reading, and plan a bearing replacement during the next planned outage.
How to diagnose intermittent operation on a Baldor Super-E motor
Intermittent stops or restarts almost always come from loose electrical connections or a worn contactor. Check the contactor first, then torque-test the conduit box terminals.
How to fix a Baldor Super-E motor making noise from coupling misalignment
Misalignment between the motor and the driven equipment creates a knocking or rumbling noise. Check soft foot first, then measure parallel and angular alignment with a dial indicator or laser tool.
How to fix overheating and excessive current draw on a Baldor Super-E motor
Overheating with high current is usually mechanical overload or supply phase imbalance. Measure phase currents, check the load, and verify supply voltage balance is within 1%.
Related learning guides
Stop fixing the same fault twice.
Dovient turns guides like this into your team's shared playbook, with AI that catches recurring issues before they break the line.