TL;DR
External leaks from between plates are almost always a gasket issue: either the frame bolts backed off or the gaskets aged out. Re-torque first, then replace gaskets if leaking continues.
What you might see
- liquid dripping from between plates on the frame edge
- liquid trail running down the frame toward the floor
- leakage increases at higher operating pressure
- gasket visible extruding past the plate edge
Likely causes
Frame bolts backing off due to thermal cycling or vibration, reducing clamping force on the gasket
Gasket material age-hardening, losing elasticity and sealing ability
Gasket extruded during a previous over-tightening event
Operating temperature or pressure exceeding the gasket material rating
Required tools
- Torque wrench sized to the frame bolts
- Vernier caliper or depth gauge to measure tightening dimension A
- Solvent wipe cloths
- Replacement gaskets per Alfa Laval M-Series part numbers
- LOTO kit
Safety first
- Do not attempt to tighten frame bolts while the unit is at full operating pressure. Reduce or stop flow first.
- Hot process fluids remain in the plates after shutdown. Verify cool and zero pressure before de-plating.
Procedure
- 1
Reduce process flow to the minimum and reduce pressure if controllable, to limit the leak while preparing for repair.
- 2
Shut down and lock out both sides. Verify zero pressure before touching the frame.
Warning: Stored thermal energy and residual process fluid pressure remain after shutdown. Allow the unit to cool and verify zero pressure before opening. - 3
Measure the current tightening dimension A of the frame (distance between the fixed and movable end plates) per the Alfa Laval instruction manual.[1]
- 4
Compare to the dimension stamped on the frame label. If A is larger than the stamped dimension, tighten the bolts evenly in a cross pattern in 2 mm increments until A matches.[1]
- 5
Restart the unit and observe the leak point for 15 minutes. If leakage stops, the re-torque resolved it.
- 6
If leakage continues after correct tightening, the gasket at that plate position has failed. De-plate and identify the leaking gasket by the wet plate edge.
- 7
Remove the damaged gasket. Clean the gasket groove with a solvent wipe and verify the groove is free of adhesive residue.
- 8
Install the new Alfa Laval-specified gasket for the M-Series model. Seat the gasket into the groove without adhesive unless the manual specifies otherwise.[1]
- 9
Reassemble and tighten to the correct A dimension. Perform a leak check at operating pressure before returning to full flow.
Sources
Alfa Laval M-Series Plate Heat Exchanger Instruction Manual, Alfa Laval
Alfa Laval M-Series PHE Instruction Manual, tightening dimension and gasket replacement procedure (general)
View source
More guides for Alfa Laval M-Series PHE
How to troubleshoot high pressure drop across an Alfa Laval M-Series heat exchanger
Rising pressure drop across the plate pack means fouling, partial blockage, or too many plates for the flow rate. Measure the delta P, run CIP, and verify the plate count against design.
How to find and fix plate leakage on an Alfa Laval M-Series heat exchanger
Internal or external leaks on a plate pack usually trace to corrosion pits or cracked plates. Isolate the unit, de-plate, perform a dye or pressure test on suspect plates, and replace the damaged ones.
How to stop flow-induced vibration on an Alfa Laval M-Series plate heat exchanger
Vibration in a plate heat exchanger usually comes from flow velocity exceeding design limits or from loose pipework supports transmitting external vibration into the frame.
How to restore heat transfer on an Alfa Laval M-Series plate heat exchanger with fouling
Reduced heat transfer almost always means fouling or scale on the plates. Run a CIP cleaning cycle, inspect the plates visually, and re-torque to the stamped dimension.
Related learning guides
Motor Troubleshooting: Symptoms to Fix
Read motor symptoms correctly and get to the root cause in minutes, not hours.
Read guideLubrication Best Practices
The most overlooked maintenance task, and how to do it right.
Read guideShaft Alignment Fundamentals
Precision alignment that prevents bearing, seal, and coupling failures.
Read guideStop fixing the same fault twice.
Dovient turns guides like this into your team's shared playbook, with AI that catches recurring issues before they break the line.