TL;DR
Main drive overload usually means a mechanical jam, a broken punch, or a drive fault. Inspect the turret and punch set before attempting a restart.
What you might see
- main drive overload fault on HMI
- press stopping mid-run
- drive current spike at fault time
- jam or unusual noise before fault
Likely causes
Broken punch or die causing a jam in the turret
Tablet jam at the ejection ramp or discharge chute
Overcompression from incorrect fill depth cam setting
Drive inverter fault or phase loss
Required tools
- Inspection flashlight
- LOTO kit
- Punch inspection tools and gauge
- Manual turret rotation tool (if applicable)
Safety first
- Never reach into the die table or punch area with the turret in an unknown state. Lock out completely before any internal access.
- Pharmaceutical dust is present inside the press casing. Wear respiratory PPE per product SOP during internal inspections.
- Broken punch tips can launch with significant force. Do not stand directly over the die table when a punch failure is suspected.
Procedure
- 1
Stop the press immediately. Lock out and tag out the main drive.
- 2
Inspect the discharge chute and tablet ejection area for a tablet jam or fragment accumulation.[1]
- 3
Manually index the turret (if provided by the press design) by one station at a time. Check for binding.
- 4
Inspect each punch and die in the turret for a broken lower punch tip or a cracked upper punch.[1]
- 5
Check the fill depth cam setting against the process order. Overfill causes excess compression force.
- 6
Review the drive inverter fault log on the press HMI for current limit trip codes.
- 7
After clearing any mechanical jam and confirming no broken tooling, restore power and attempt a jog start at low speed to verify free rotation before resuming production.
Sources
Fette Compacting Fette FE 1200i / 3090 Tablet Press general technical documentation, Fette Compacting
Fette FE 1200i / 3090 tablet press general drive overload and punch jam procedures (general)
More guides for Fette Compacting Fette FE 1200i / 3090
How to fix punch sticking on a Fette FE 1200i / 3090 tablet press
Punch sticking means material is adhering to the punch face. Inspect punch surface quality, verify lubrication, and check product moisture before adjusting compression force.
How to fix out-of-spec weight variation on a Fette FE 1200i / 3090 tablet press
Weight variation on a rotary tablet press is most often a feed system or fill depth problem. Check the feed frame paddles, hopper level, and die fill depth before adjusting.
Related learning guides
Vibration Analysis Basics
What your equipment is telling you before it fails.
Read guideBearing Replacement: When, Why, and How
The right-way guide to bearing replacement, and the warning signs you should never skip.
Read guidePump Failure: 8 Common Causes
The most frequent pump failure modes and how to prevent them.
Read guideStop fixing the same fault twice.
Dovient turns guides like this into your team's shared playbook, with AI that catches recurring issues before they break the line.